This video shows vibrational test following IEC 60068-2-6 standard on a GD160Q green drive tubular linear motor moving forward and backward between two prositions.
Vibrations creates mechanical stress upto 4.G on cables, connectors, integrated encoder electronics and motor windings. Complete test duration is 8 hours on three different axis directions.
This test equipment is also realised by 2 x GD250XS tubular linear motor in parallel drive configuration controlled by one drive.
This machine is able to create sinusoidal vibration from low frequency to medium frequency upto 35 Hz with different strokes.
For further information on our product lines, please visit our website: https://www.nitek.it