https://elkom.com.tw/
24 direct open collector outputs with NPN transistors for driving external 12V relays
1 +12VDC output for relays
32 outputs based on four DS2408 1-wire extension boards
56 total output count
PLC2011C0 can be used for controlling of 28 roller shutters (up and down)
Each output can operate in many modes of operation
1-Wire: Bus for 32 x DS18B20, DS18S20 or DS1822 (+5V, DQ and GND)
1-Wire: 5VDC voltage regulator is built in
1-Wire: Built-in 32 temperature regulators based on DS18B20, DS18S20, DS1822
1-Wire: Each 1-Wire DS thermometer can act as a temperature regulator with hysteresis
1-Wire: Built-in 16 differential temperature regulators with hysteresis
1-Wire: Each neighboring pair of DS thermometers can act as differential thermostat
1-Wire: Each thermostat has individually programmable hysteresis or differential hysteresis
1-Wire: Differential thermostats have individually programmable minimum active temperature
1-Wire: Differential thermostats have individually programmable maximum active temperature
1-Wire: Each DS thermometer can be used as under temperature alarm (freezing alarm)
1-Wire: Each DS thermometer can be used as over temperature alarm (fire alarm)
1-Wire: Each thermostat can operate in cooling or heating mode
1-Wire: Each differential thermostat can operate in cooling and heating mode at the same time
DMX512: Bus (protocol) for RGB LED lighting, dimming and light scenes
DMX512: 128 channels available
DMX512: Refreshing rate 175Hz
DMX512: Light scene editors, light composers in software
DMX512: Works on standard RS485 bus
DMX512: Single, optically isolated 12-24VDC input for set reset and long press functions
Modbus: TCP/IP master over the Ethernet/LAN/Internet
Modbus: UDP/IP master over the Ethernet/LAN/Internet
Modbus: Can be used to upgrade other PLC devices and systems to the Android remote control
Modbus: Works as a bridge between the internet and user’s local LAN
Modbus: PLC2011C0 can transfer all it’s assets into user’s third party PLC or computer
Modbus: thermometers, variables and output states can be transmitted
Built-in timers and Astronomical Timer
Operation via the internet using PCs or mobile phones or tablets with the Android operating system
PLC2011C0 has LAN interface with a RJ-45 connector and USB 2.0
Strongly encrypted data transmission using AES-256/SHA-256 algorithms
Cooperation with the PLC2011A0 and PLC2011B0 in the LAN network
Operation of all devices using one software for PC or a mobile device
Post time: Aug-08-2017