Special Design for TU-028 thermostatic cartridge wax sensor for sanitary ware for Danish Importers

Special Design for
 TU-028 thermostatic cartridge wax sensor for sanitary ware for Danish Importers

Short Description:

Product Detail

Product Tags

We often stay with the principle "Quality Very first, Prestige Supreme". We have been fully committed to supplying our consumers with competitively priced high-quality goods, prompt delivery and skilled provider for Water Cooling Thermostat , Wax Thermostatic Element , Sanitary Ware , We're self-assured to create wonderful achievements while in the potential. We've been hunting forward to becoming one of your most trustworthy suppliers.
Special Design for TU-028 thermostatic cartridge wax sensor for sanitary ware for Danish Importers Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.


Product detail pictures:

Special Design for
 TU-028 thermostatic cartridge wax sensor for sanitary ware for Danish Importers detail pictures


We insist on offering high-quality production with great enterprise concept, honest product sales and also the finest and fast service. it will bring you not only the superior quality solution and huge profit, but the most significant should be to occupy the endless market for Special Design for TU-028 thermostatic cartridge wax sensor for sanitary ware for Danish Importers, The product will supply to all over the world, such as: Eindhoven , Mexico , Iraq , There are advanced producing & processing equipment and skilled workers to ensure the products with high quality. We have found an excellent before-sale, sale, after-sale service to ensure the customers that could rest assured to make orders. Until now our products are now moving on fast and very popular in South America, East Asia, the Middle east, Africa, etc.



  • Check us out at https://physics.tutorvista.com

    How to Calibrate a Thermometer

    Thermometers can be calibrated either by comparing them with other certified thermometers or by checking them against known fixed points on the temperature scale. The best known of these fixed points are the melting and boiling points of pure water. (Note that the boiling point of water varies with pressure, so this must be controlled.)
    The traditional method of putting a scale on a liquid-in glass or liquid-in-metal thermometer was in three stages:
    1.Immerse the sensing portion in a stirred mixture of pure ice and water and mark the point indicated when it had come to thermal equilibrium.
    2.Immerse the sensing portion in a steam bath at 1 standard atmosphere (101.3 kPa; 760.0 mmHg) and again mark the point indicated.
    3.Divide the distance between these marks into equal portions according to the temperature scale being used.
    Other fixed points were used in the past are the body temperature (of a healthy adult male) which was originally used by Fahrenheit as his upper fixed point (96 °F (36 °C) to be a number divisible by 12) and the lowest temperature given by a mixture of salt and ice, which was originally the definition of 0 °F (−18 °C). (This is an example of a Frigorific mixture). As body temperature varies, the Fahrenheit scale was later changed to use an upper fixed point of boiling water at 212 °F (100 °C).
    These have now been replaced by the defining points in the International Temperature Scale of 1990, though in practice the melting point of water is more commonly used than its triple point, the latter being more difficult to manage and thus restricted to critical standard measurement. Nowadays manufacturers will often use a thermostat bath or solid block where the temperature is held constant relative to a calibrated thermometer. Other thermometers to be calibrated are put into the same bath or block and allowed to come to equilibrium, then the scale marked, or any deviation from the instrument scale recorded. For many modern devices calibration will be stating some value to be used in processing an electronic signal to convert it to a temperature.

    Please like our facebook page
    https://www.facebook.com/tutorvista Follow us at: https://plus.google.com/+tutorvista/



    DEFINOX – Butterfly Valve Actuator – DPAX – Maintenance

    Ceylan Elektronik / BURSA

    Tel: 0.224.443.23.00

    Send your message to us:

    INQUIRY NOW
    • * CAPTCHA: Please select the Truck

    Related Products

    INQUIRY NOW
    • * CAPTCHA: Please select the Star

    WhatsApp Online Chat !