Professional Design TU-1H05 thermal wax actuator for thermostatic radiator valve for Mumbai Importers

Professional Design
 TU-1H05 thermal wax actuator for thermostatic radiator valve for Mumbai Importers

Short Description:

Product Detail

Product Tags

With advanced technologies and facilities, strict high quality regulate, reasonable price tag, excellent support and close co-operation with shoppers, we have been devoted to furnishing the best benefit for our buyers for Wax Linear Actuator , Energe Wax Manufacturers , Automatic Temperature Control Switch , We welcome shoppers, enterprise associations and buddies from all areas of your environment to speak to us and request cooperation for mutual gains.
Professional Design TU-1H05 thermal wax actuator for thermostatic radiator valve for Mumbai Importers Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.


Product detail pictures:

Professional Design
 TU-1H05 thermal wax actuator for thermostatic radiator valve for Mumbai Importers detail pictures


We now have a skilled, performance team to supply good quality services for our consumer. We often follow the tenet of customer-oriented, details-focused for Professional Design TU-1H05 thermal wax actuator for thermostatic radiator valve for Mumbai Importers, The product will supply to all over the world, such as: Croatia , Milan , Jakarta , High output volume, top quality, timely delivery and your satisfaction are guaranteed. We welcome all inquiries and comments. We also offer agency service---that act as the agent in china for our customers. If you are interested in any of our products or have an OEM order to fulfill, please feel free to contact us now. Working with us will save you money and time.



  • Gas Pipe Sealant Warning!! Use Great White Pipe Joint. The one shown in the video is incorrect.

    READ ALL THE DESCRIPTION BEFORE PROCEEDING. CALL THE PROFESSIONAL IF NOT SURE.

    Gas heater stopped working. This is a video in two parts. Check out the second video here (https://youtu.be/vO1QRihJuqk). Which will take you from troubleshooting the problem, getting familiar with the gas heater controls & guide you with information & brief details on replacement of the Gas Valve Assembly.

    If your gas heater is under warranty for parts & labor, then it is best to call out the professionals. This video should make it easy for you to verify the problem & if you feel adventurous & want to do it your self, then make sure you read all the instructions & safety warnings specific to your model of gas heater before proceeding. If you have any questions, please contact me via my channel.

    Tags :
    Ctrl z TV, Pilot light won’t stay lit up, Gas water heater problems, Gas water heater troubleshooting, Gas valve troubleshooting, Gas valve problem, Honeywell gas thermostat.

    FAQs:

    1. How to Reset your Thermal Switch.
    Answer:
    Step1:Watch the part of the video at 2m & 26 seconds.https://youtu.be/k1qM-ZbYdWo?t=2m26s, remove the two leads from the controller. Trace the wires to the thermal switch & follow step 2
    Step 2:Reset the thermal switch or button on your water heater. If your water heater has a thermal reset switch, flip it. If your water heater has a thermal reset button, press & hold it for up to 4 seconds to reset your appliance. See this google images link to see typical places for the reset button, it is mostly on the thermal switch. Plastic piece which is not spring loaded. Thats how mine is.

    2. Your video was going very well until it showed you trying to remove the valve. It shows you turning it to the right, then the left & then trying to pull it out & it not coming out. Then you insert a (Recap) in the video & it never shows how you managed to get it out. Can you please explain?
    Answer:
    I had to turn anti-clock wise (left turns) to completely unscrew the valve from the heater body. The reason why I happened to go right is I realized I had some water leaking & assuming the worst case that water somehow had filled back up into the tank. I did have a leak in my water valve which caused the tank to slowly fill back up. In the end, I drained it & continued with unscrewing (anti-clockwise) till the valve was out. In the beginning it felt like I was going to break it as the plastic body is flimsy. Use your desecration on amount of pressure to apply. If its too tight, left & right turns will help loosen it up. Hope that helps.

    3. Hi I have a now 2 year old Kenmore water heater which is supposed to carry a 12 year warranty. My gas valve has gone out & has left me with no hot water for over a week.
    Answer:
    Sears tells me that this part isn’t under warranty & wants 200.00 for the part. I seem to get a different answer from them each time, but it seems they imply that as a homeowner, you have to contact a sears qualified technician & pay their labor before they will provide the part under warranty. Did you have all these problems getting your part?
    My situation was different. I had to contact the heater manufacturer as my home warranty of 1 year was up. However when I called the American Water Heaters warranty support, they performed troubleshooting over the phone & pretty soon we were on our way to replacement parts. Sears on the other h& seem to be violating consumer policies. Here is a link I found about one gentlemen trying to get parts. Good luck with it.

    https://rankexploits.com/musings/2014/how-i-got-sears-to-send-me-warranty-parts-i-hope/

    4.Wait, what happened at 3:07 & at 3:35 ? — The most important parts of this video are not there, that is, the parts where the line gets connected back to the valve? WTF??
    The FTW happened was my camera is faulty & had stopped recording. However , what I did was just unscrewed all the connections. They are all threaded. Now, the part where I am unscrewing the valve, I had to stop recording as I found some water ( few gallons ),which gushed out. So even though you did a water drain, make sure that it is completely drained. Oh yeah, the missing video would have been , me rotating the valve anti clock wise. That’s it. I hope your tank gets back to work.

    5. My pilot light comes on ,but after I release the button after holding it for a minute,the pilot gos out,I used my field piece digital meter & set it on millivolts dc & connected my leads to the two wires on the water heater thermocouple wires like you did & the volts went up to 440 in a minute,or a little before a minute & then my meter gets no more reading,it shows OL on my meter,my question is shouldn’t I still have a millivolts reading on my meter even after a minute?

    Answer:
    OL could mean Over Limit, which means you still have voltage but your meter cannot read it. Do you have a higher setting or another meter?



    Dislocations in the Bucky Gel actuator with respect to the AC voltage being applied.

    Send your message to us:

    INQUIRY NOW
    • * CAPTCHA: Please select the Plane

    Related Products

    INQUIRY NOW
    • * CAPTCHA: Please select the Car

    WhatsApp Online Chat !