Original Factory TU-1J04 thermal wax actuator for industrial thermostatic water regulations mixing valve to Austria Factories

Original Factory
 TU-1J04 thermal wax actuator for industrial thermostatic water regulations mixing valve to Austria Factories

Short Description:

Product Detail

Product Tags

Reliable good quality and very good credit standing are our principles, which will help us at a top-ranking position. Adhering to your tenet of "quality 1st, purchaser supreme" for Automatic Temperature Control Washer , Wax Sensor , Electric Linear Actuator 12v , We just not only deliver the high-quality to our customers, but far more even important is our greatest service along with the competitive price tag.
Original Factory TU-1J04 thermal wax actuator for industrial thermostatic water regulations mixing valve to Austria Factories Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.


Product detail pictures:

Original Factory
 TU-1J04 thermal wax actuator for industrial thermostatic water regulations mixing valve to Austria Factories detail pictures


Good quality comes initial; company is foremost; small business is cooperation" is our business philosophy which is frequently observed and pursued by our business for Original Factory TU-1J04 thermal wax actuator for industrial thermostatic water regulations mixing valve to Austria Factories, The product will supply to all over the world, such as: Curacao , Indonesia , Malawi , They are sturdy modeling and promoting effectively all over the world. Never ever disappearing major functions within a quick time, it's a have to in your case of fantastic good quality. Guided by the principle of Prudence, Efficiency, Union and Innovation. the corporation. ake an excellent efforts to expand its international trade, raise its organization. rofit and raise its export scale. We've been confident that we've been going to have a bright prospect and to be distributed all over the world in the years to come.



  • How to Wire PCON CA – Wiring Controller for IAI Electric Actuator – ROBO Cylinder

    https://www.intelligentactuator.com/controllers-teach-catalogs/

    Accessary Connector (Plug)
    0V is connected to “0V”…
    Use AWG16 Wire…
    24V is connected to “24V”…
    Again, Use AWG16 Wire…
    MPI and M10 Should come Jumpered…
    24V from Controllers goes to the Motor…
    Use AWG20 Wire for S1, S2, EMG-, BKRLS…
    24V goes to S1, which is connected to S2 internally…
    S2 is connected to EMG-…
    – see details on the video —

    Field Network Controllers
    ROBO Cylinder Position Controller PowerCON 150: PCON-CA
    ROBO Cylinder Position Controller High-thrust Motor Type: PCON-CFA

    1: Supporting seven major eld networks
    DeviceNet, CC-Link, PROFIBUS-DP, CompoNet, MECHATROLINK (I, II), EtherCAT and EtherNet/IP are supported. Key
    features include wire-saving, direct numerical specication, position number specication, and current position read.

    2: PCON-CFA for high-thrust motors

    Supported Actuators:
    PCON-CA: ROBO Cylinder RCP4 / RCP3 / RCP2 series
    PCON-CFA: ROBO Cylinder RCP2-RA8C / RA8R / RA10C / HS8C / HS8R series, ROBO Cylinder splash-proof RCP2W-SA16C / RA10C series

    Field Network Type:
    DeviceNet, CC-Link, PROFIBUS-DP, CompoNet, MECHATROLINK, EtherCAT, EtherNet/IP



    https://www.1aauto.com/1A/HeatingandACControls/GMC/Sierra/1AHCX00042?utm_source=YouTube&utm_medium=description&utm_campaign=videodesc&utm_term=_Suo7gNvLTM
    1A Auto Shows you how to install, repair, fix, change or replace a broken or not working AC/Heater air temperature control. This video is applicable to the 99, 00, 01, 02, 03, 04, 05, and 06 Chevy Silverado, Sierra, and Suburban models.

    Send your message to us:

    INQUIRY NOW
    • * CAPTCHA: Please select the Flag

    Related Products

    INQUIRY NOW
    • * CAPTCHA: Please select the Tree

    WhatsApp Online Chat !