OEM/ODM China TU-1D091 thermal wax actuator for industrial thermostatic water regulations mixing valve Export to British

OEM/ODM China
 TU-1D091 thermal wax actuator for industrial thermostatic water regulations mixing valve Export to British

Short Description:

Product Detail

Product Tags

Quality First,and Customer Supreme is our guideline to provide the best service to our customers.Nowadays, we are trying our best to become one of the best exporters in our field to meet customers more need for Paraffin Wax Buy , Thermal Actuator Uponor , Motorcycle Enriching Valve , We have a professional team for international trade. We can solve the problem you meet. We can provide the products you want. Please feel free to contact us.
OEM/ODM China TU-1D091 thermal wax actuator for industrial thermostatic water regulations mixing valve Export to British Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.


Product detail pictures:

OEM/ODM China
 TU-1D091 thermal wax actuator for industrial thermostatic water regulations mixing valve Export to British detail pictures


Good quality comes to start with; service is foremost; organization is cooperation" is our enterprise philosophy which is regularly observed and pursued by our firm for OEM/ODM China TU-1D091 thermal wax actuator for industrial thermostatic water regulations mixing valve Export to British, The product will supply to all over the world, such as: Algeria , Luxembourg , Moscow , Ensuring high product quality by choosing the best suppliers, we have also implemented comprehensive quality control processes throughout our sourcing procedures. Meanwhile, our access to a large range of factories, coupled with our excellent management, also ensures that we can quickly fill your requirements at the best prices, regardless the order size.



  • The Samson Type 3730-3 is an electro-pneumatic valve positioner with HART® communication for use with linear and quarter-turn industrial valves.

    The positioner ensures a predetermined assignment of the valve position to the input signal. It compares the input signal received from a control system to the travel or rotational angle of the control valve and issues a corresponding output signal pressure.

    Special Features:

    Simple attachment to all common linear and rotary actuators with interface for SAMSON direct attachment, NAMUR rib, valves with rod-type yokes according to IEC 60534-6-1 or to rotary actuators according to VDI/ VDE 3845.

    Any desired mounting position of the positioner.

    Simple single-knob, menu-driven operation.

    LCD easy to read in any mounted position due to selectable reading direction.

    Configurable with a PC over the SSP interface using the TROVIS-VIEW software.

    Variable, automatic start-up with four different initialization modes
    Preset parameters – only values deviating from the standard need to be adjusted.

    Calibrated travel sensor without gears susceptible to wear.

    Sub-initialization mode (substitution) allows the positioner to be started up in case of emergency whilst the plant is running without the valve moving through the whole travel range.

    Permanent storage of all parameters in EEPROM (protected against power failure).

    Two-wire system with small electrical load between 300 and 350 Ω depending on version.

    Adjustable output pressure limitation.

    Tight-closing function.

    Continuous monitoring of zero point.

    Integrated temperature sensor and operating hours counter.

    Two standard programmable position alarms.

    Self-diagnostics; alarms as condensed state conforming to NAMUR Recommendation NE 107, issued over a fault alarm contact or optional analog position transmitter.

    Integrated EXPERTplus diagnostics (u T 8389 EN) suitable for throttling and on/off valves and with additional partial stroke test for valves in safety-instrumented systems.

    RENCOR Controls
    21 Sullivan Parkway
    Fort Edward, NY 12828
    Phone: (800) 777- 4174
    Fax: (518)747- 4176



    This video demonstrates the operation a small (Worcester) motor operated ball valve also known as an “MOV”. Also known as an “electric actuator”, motor operators come in a wide variety of sizes and styles. Some electric actuators are intended for quarter-turn valves (such as ball and butterfly valves), while others are designed to operate linear valves (such as gate and globe valves).

    The MOV / electric actuator consists of an electric motor with a gearbox assembly sized correctly to rotate the shaft of a valve. Most MOVs operate at 120, 240 or 480 volt, single or three phase. Basic features include adjustable limit switches to limit valve travel and to notify valve status, directional settings, analog inputs to allow for precise control, analog outputs to provide a feedback signal and digital communications. MOV enclosures can be either NEMA 4, NEMA 4X and NEMA 7 and are available in a wide range of torque outputs to match the valve it is operating.

    Send your message to us:

    INQUIRY NOW
    • * CAPTCHA: Please select the Heart

    Related Products

    INQUIRY NOW
    • * CAPTCHA: Please select the Heart

    WhatsApp Online Chat !