OEM/ODM China Medial Temperature Wax Supply to Stuttgart
Short Description:
Product Detail
Product Tags
OEM/ODM China Medial Temperature Wax Supply to Stuttgart Detail:
Automatic Temperature Regulating Agent Series is a kind of thermal expansion materials, which depends on principles that the substance expands when it is heated and constricts when it is cooled and a liquid is incompressible. It can automatically regulate temperature. When the ambient temperature goes up to the special value, Automatic Temperature Regulating Agent goes up to the special temperature with the ambient temperature, its unit volume increases. When the ambient temperature falls down to special value, Automatic Temperature Regulating Agent also falls down to the special temperature with the ambient temperature, its unit volume reduces. The agent is loaded in the purpose-made thermostatic element. The variation of ambient temperature takes a pressure and the thermostatic element takes a change, and this change brings the movement of either the appurtenance of the thermodynamic component or itself, thereby carrying out the automatic opening & closing function. All sorts of temperature controllers and the electrical switches are developed depending on the physical feature of Automatic Temperature Regulating Agent. It has been widely used in the fields of refrigeration, auto-control system, automobile industry, petrochemical industry, sanitary ware, heating and ventilating, electric electron, building, space & aviation etc.
Model Number |
Appearance (Normal Temperature) |
Quality Standard |
|||
Range of Temperature Control |
Effective Distance Travel |
Water-Solubility Acid and Alkali |
Mechanical Impurity |
||
A45 |
Powder, Slice , Column |
45/55 |
7 |
Non. |
Non. |
A45-1 |
Powder, Slice , Column |
45/55 |
10 |
Non. |
Non. |
A45-2 |
Powder, Slice , Column |
45/60 |
11 |
Non. |
Non. |
A48 |
Powder, Slice , Column |
48/60 |
7 |
Non. |
Non. |
A50 |
Powder, Slice , Column |
50/60 |
8 |
Non. |
Non. |
A50-1 |
Powder, Slice , Column |
50/75 |
6 |
Non. |
Non. |
A51 |
Powder, Slice , Column |
51/60 |
10 |
Non. |
Non. |
A52 |
Powder, Slice , Column |
52/55 |
3 |
Non. |
Non. |
A53 |
Powder, Slice , Column |
53/59 |
7 |
Non. |
Non. |
A54 |
Powder, Slice , Column |
54/67 |
9 |
Non. |
Non. |
A55 |
Powder, Slice , Column |
55/62 |
7 |
Non. |
Non. |
A55-1 |
Powder, Slice , Column |
55/65 |
10 |
Non. |
Non. |
A55-2 |
Powder, Slice , Column |
55/70 |
11 |
Non. |
Non. |
A57 |
Powder, Slice , Column |
57/66 |
10 |
Non. |
Non. |
A58 |
Powder, Slice , Column |
58/70 |
8 |
Non. |
Non. |
A60 |
Powder, Slice , Column |
60/70 |
6 |
Non. |
Non. |
A60-1 |
Powder, Slice , Column |
60/70 |
10 |
Non. |
Non. |
A60-2 |
Powder, Slice , Column |
60/75 |
4 |
Non. |
Non. |
A60-3 |
Powder, Slice , Column |
60/75 |
11 |
Non. |
Non. |
A60-4 |
Powder, Slice , Column |
60/80 |
2 |
Non. |
Non. |
A60-5 |
Powder, Slice , Column |
60/85 |
10 |
Non. |
Non. |
A60-6 |
Powder, Slice , Column |
60/100 |
5 |
Non. |
Non. |
A63 |
Powder, Slice , Column |
63/75 |
8 |
Non. |
Non. |
Product detail pictures:

We believe that long term partnership is a result of high quality, value added service, rich experience and personal contact for OEM/ODM China Medial Temperature Wax Supply to Stuttgart, The product will supply to all over the world, such as: Cape Town , UAE , Los Angeles , Most problems between suppliers and clients are due to poor communication. Culturally, suppliers can be reluctant to question things they do not understand. We break down those barriers to ensure you get what you want to the level you expect, when you want it. Faster delivery time and the product you want is our Criterion .
Our web site: https://www.techtrixinfo.com/
Plz Join Our Face Book Page:https://www.facebook.com/pages/TechTrixInfo/271447906234307
Our Android app Google play: https://play.google.com/store/search?q=techtrixinfo&c=apps
This video, explains about the working and function of a radiator cap, how valve mechanism in it increased the boiling point of the coolant and maintains a positive pressure. If genuine radiator cap is not used it can result in the failure of engine due to overheating.
We need your support to keep going: Please click like button, comment, share in social media, join our face book page https://www.facebook.com/pages/TechTrixInfo/271447906234307 or please bookmark our site www.techtrixinfo.com
You can subscribe to us for more technical videos; thanks for your support have a great day.
Related topics:
Radiator cap in car, radiator cap pressure, radiator cap pressure tester, radiator cap boiling point, radiator cap boiling over, radiator cap pressure boiling point, radiator cap pressure vs boiling point, , radiator cap for high lifter products radiators, radiator cap vs commodore, radiator cap and overheating, radiator cap or thermostat, radiator cap and neck, radiator cap with temperature gauge, radiator cap on, radiator cap with, radiator and cap tester, radiator cap with lever, radiator cap with anode, radiator cap with temp gauge, radiator cap issues, radiator cap is stuck, radiator cap is cold, radiator cap is bad, radiator cap in car, radiator cap operation, radiator cap loose, radiator cap leaking, radiator cap left off, radiator cap removal tool, radiator cap replacement, radiator cap release pressure, radiator cap rating, radiator cap adapter, radiator cap autozone, radiator cap assembly, radiator cap quick fix, radiator cap blown off, radiator cap not holding pressure, radiator cap not getting hot, radiator cap not tight, radiator cap universal, radiator cap gasket, radiator cap gauge, radiator cap diagram, radiator cap dimension, radiator cap how it works, radiator cap hissing, radiator cap failure, radiator cap funnel, radiator cap extension, radiator cap explosion, radiator cap missing, radiator cap melted, radiator cap keeps breaking, radiator cap keeps popping off, radiator cap overheat, radiator cap vacuum valve, radiator cap valve, radiator cap cost, radiator cap cover, radiator cap jeep, radiator cap type, radiator cap thermometer