Goods high definition for TU-1C01 thermal wax actuator for air conditioner and compressor Export to India

Goods high definition for
 TU-1C01 thermal wax actuator for air conditioner and compressor Export to India

Short Description:

Product Detail

Product Tags

We pursue the management tenet of "Quality is superior, Service is supreme, Reputation is first", and will sincerely create and share success with all clients for Thermostatic Element , Radiator Thermostatic Valve , Automatic Temperature Control Hvac , We will do our best to meet or exceed customers' requirements with quality products, advanced concept, and efficient and timely service. We welcome all customers.
Goods high definition for TU-1C01 thermal wax actuator for air conditioner and compressor Export to India Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.


Product detail pictures:

Goods high definition for
 TU-1C01 thermal wax actuator for air conditioner and compressor Export to India detail pictures


We continue to keep increasing and perfecting our solutions and service. At the same time, we operate actively to do research and enhancement for Goods high definition for TU-1C01 thermal wax actuator for air conditioner and compressor Export to India, The product will supply to all over the world, such as: UK , luzern , Uruguay , Our qualified engineering team will usually be prepared to serve you for consultation and feedback. We've been able to also deliver you with absolutely free samples to meet your needs. Best efforts might be made to offer you the ideal service and items. For anyone who is interested in our company and products, be sure to make contact with us by sending us emails or contact us right away. In order to know our solutions and organization. ar more, you can come to our factory to determine it. We are about to usually welcome guests from around the globe to our corporation. o create small business relations with us. Please genuinely feel no cost to speak to us for enterprise. nd we believe we have been gonna share the most effective trading practical experience with all our merchants.



  • Mercedes single zone climate control trouble code readout,and reset procedure..Many Mercedes models used this same climate control panel…look closely to be sure yours is the same…dual zone climate controls have a different procedure and some specific codes..r129,w210,w124,w202,w140 and others, all can possibly have this panel as standard equipment depending on which country and what equipment level the car has..this car is a 1997 c230

    FAULT CODES
    DTC Readout Descriptions

    026 CAN Bus Communication
    226 In-Car Air Temperature Sensor
    227 Outside Air Temperature Sensor
    228 Heater Core Temperature Sensor
    230 Evaporator Temperature Sensor
    231 Engine Coolant Temperature Sensor
    232 Refrigerant Pressure Sensor
    233 Refrigerant Temperature Sensor
    241 Refrigerant Level
    416 Coolant Circulation Pump
    417 Left Duovalve (Water Valve)
    418 Right Duovalve (Water Valve)
    419 A/C Compressor Electromagnetic Clutch
    420 Closed (Idle) Throttle Speed Increase
    421 Pulse Module
    422 Serial Interface Connection (K1) to Instrument Cluster
    451 Diverter Flap
    452 Blend Air Flap
    453 Fresh/Recirculated Air Flap Long Stroke
    454 Fresh/Recirculated Air Flap Short Stroke
    455 Defroster Outlet Flap Long Stroke
    456 Defroster Outlet Flap Short Stroke
    457 Footwell Flap Long Stroke
    458 Footwell Flap Short Stroke
    459 Serial Interface Connection (K2) to Instrument Cluster
    462 Wide Open Throttle (WOT) Position Signal – Diesel Engine Only follow me on twitter https://twitter.com/fupabox



    Double Acting:0°-90°
    Output torque(0.5Mpa.Nm):16.6-2695
    Operating Temperature:-20℃-+80℃
    Connect apeopple’s thread:1/8

    Send your message to us:

    INQUIRY NOW
    • * CAPTCHA: Please select the Plane

    Related Products

    INQUIRY NOW
    • * CAPTCHA: Please select the Cup

    WhatsApp Online Chat !
    Close