Factory Wholesale PriceList for TU-1H02 thermal wax actuator for thermostatic radiator valve Export to Seychelles
Short Description:
Product Detail
Product Tags
Factory Wholesale PriceList for TU-1H02 thermal wax actuator for thermostatic radiator valve Export to Seychelles Detail:
1. Operation Principle
The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.
2. Characteristic
(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.
(2)Temperature control is reliable and nicety
(3)No shaking and tranquilization in working condition.
(4)The element doesn’t need special maintenance.
(5)Working life is long.
3.Main Technical Parameters
(1)Handspike’s height may be confirmed by drawing and technical parameters
(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.
(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.
(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.
(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.
Product detail pictures:
Our well-equipped facilities and superb good quality control throughout all stages of manufacturing enables us to guarantee total buyer gratification for Factory Wholesale PriceList for TU-1H02 thermal wax actuator for thermostatic radiator valve Export to Seychelles, The product will supply to all over the world, such as: Argentina , Sudan , Cannes , Our company has abundant strength and possesses a steady and perfect sales network system. We wish we could establish sound business relationships with all customers from at home and abroad on the basis of mutual benefits.
There are several troubleshoots the furnace sticker lists that might be the problem. I point out several of them. If you dont care to learn anything about the furnace and what sets off an error code 33, then just skip to 6:00 to see the fix. But for most people I think it would be helpful to watch the whole thing, (sure would have saved me a ton of time.) But now I know a lot about furnaces!
#33 LIMIT CIRCUIT FAULT – Indicates a limit, draft safeguard, flame rollout, or blocked vent switch (if used) is open. Blower will run for 4 minutes or until open switch remakes whichever is longer. If longer than 3 minutes, code changes to lockout #13. If open less than 3 minutes status code #33 continues to flash until blower shuts off. Flame Rollout switch and BVSS require manual reset. Check for:
- Restricted Vent
- Proper Vent Sizing
- Loose blower wheel
- Excessive wind
- Dirty filter or restricted duct system
- Defective blower motor or capacitor
- Defective switch or connections
- Inadequate combustion air supply (flame rollout switch open)
Bryant Heating and Cooling Systems
Natural Gas
Central Furnace
Model Number 310AAV048135 / 310AAV048135ACJA
Manufactured JUL 2006
1/2 HP Motor
how to troubleshoot and fix an electric kettle.