Factory supplied TU-1D091 thermal wax actuator for industrial thermostatic water regulations mixing valve to Czech Factories

Factory supplied
 TU-1D091 thermal wax actuator for industrial thermostatic water regulations mixing valve to Czech Factories

Short Description:

Product Detail

Product Tags

We believe that long term partnership is a result of high quality, value added service, rich experience and personal contact for Thermostatic Element For Building Heating , Corner Radiator Valves , Coleman Air Compressor Parts , We, with open arms, invite all interested buyers to visit our website or contact us directly for further information.
Factory supplied TU-1D091 thermal wax actuator for industrial thermostatic water regulations mixing valve to Czech Factories Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.


Product detail pictures:

Factory supplied
 TU-1D091 thermal wax actuator for industrial thermostatic water regulations mixing valve to Czech Factories detail pictures


Using a complete scientific high quality management program, superior high quality and superior faith, we acquire great reputation and occupied this industry for Factory supplied TU-1D091 thermal wax actuator for industrial thermostatic water regulations mixing valve to Czech Factories, The product will supply to all over the world, such as: Cape Town , Iraq , Sudan , Relying on superior quality and excellent post-sales, our products sell well in America, Europe, the Middle East and South Africa. We are also the appointed OEM factory for several worlds' famous products brands. Welcome to contact us for further negotiation and cooperation.



  • In this video we show How to replace the oxygen (O2) sensor also known has Air Fuel Ratio sensor on the Nissan Frontier V6 (3300 – VG33E) engine.Here you will see the difference between Bank #1 (right side)and Bank #2(left side) heated (4-wire) oxygen sensors. Replacing the oxygen sensor every 60-70,000 miles is an effort to help conserve fuel/gasoline.The oxygen sensor are not the only device to harness against waste consumption. The coolant temperature sensor at the thermostat housing reports to the computer, the computer commands the cooling fans through the fuel/relay box. Some model will be equipped with dual cooling fans. One for normal operation is the 1st fan. The 2nd fan is for air condition operation and over-heating conditions. If the Tstat remain stuck “close” the two fan will operate and coolant will overflow in its reserve container. The Tstat ONLY control engine temperature. The fans operation and gauge help radiates any heat or over heating base on ambient air temperature and operator.

    The oxygen sensor is a state EPA “enviromental term” all so known has a EGT – exhaust gas temperature sensor sends millivoltage(data) to the ecm – engine control module for fuel injector control and its flow rate(impedeance). The oxygen sensor key roll is to measure the combustion flame/temperature .the ideal temperature for anything above 75% throttle is .870mv – .900mv output at the exhaust gas temperature/oxygen sensor. The oxygen(o2) sensor also work in conjuction with the Mass Air Flow Meter/sensor for fuel injector control. So the oxygen sensor can also be conside a Air Fuel Ratio sensor and the Mass Air Flow meter is mounted on the intake manifold duct.

    M18 sensors – Install finger tight then 1/2 – 3/4 turn with wrench/ O2 sensor socket.26-33ft. lbs
    M12 sensors – Install finger tight then 3/4 – 1 turn with wrench / O2 sensor socket.13.2-17ft. lbs.

    APPLICATION: 2003 NISSAN FRONTIER EX, Xterra
    3300 CC ENGINE 4X4

    PLEASE – RATE – COMMENT AND SUBSCRIBE.

    * DO NOT drop or use an oxygen sensor that has been dropped as this may have caused shock damage to the ceramic cell.
    * DO NOT use any compound on or around the sensor unless labeled as oxygen sensor friendly products.
    * DO NOT use impact wrench or conventional socket type wrench to install sensor.
    * DO NOT allow sensor or lead wire to touch exhaust manifold or any other hot component.
    * DO NOT expose this product to water,oil,windshield cleaner, anti-corrosion oil,grease,terminal cleaner, etc.
    * DO NOT use leaded fuels, silicone or metal based additives
    * DO NOT store under high humidity conditions will promote rusting.
    WARNING : Anti-seize compound may cause irritation to the skin or eyes. In case of contact, wash affected area with soap and water. In case of eye contact, Flush with water for 15 minutes. If irritation persists, consult a physician. If swallowed, DO NOT induce vomiting.

    KEEP OUT OF REACH OF CHILDREN.



    In this Alfa Laval 360° Service & Maintenance video we will demonstrate how to change product-wetted seals and how to change a double mechanical shaft seal on the Alfa Laval LKH Prime pump range. With Alfa Laval service you maximize the reliability and uptime of your equipment. The result is superior performance throughout the equipment life cycle – performance that puts you ahead of competition.

    https://www.alfalaval.com/lkhprime

    https://www.alfalaval.com/lkhprimeup

    Send your message to us:

    INQUIRY NOW
    • * CAPTCHA: Please select the Truck

    Related Products

    INQUIRY NOW
    • * CAPTCHA: Please select the Car

    WhatsApp Online Chat !