1. Operation Principle
The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.
2. Characteristic
(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.
(2)Temperature control is reliable and nicety
(3)No shaking and tranquilization in working condition.
(4)The element doesn’t need special maintenance.
(5)Working life is long.
3.Main Technical Parameters
(1)Handspike’s height may be confirmed by drawing and technical parameters
(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.
(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.
(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.
(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.
Product detail pictures:
With sophisticated technologies and facilities, strict top quality handle, reasonable value, exceptional support and close co-operation with clients, we are devoted to furnishing the ideal worth for our clients for Factory selling TU-1H05 thermal wax actuator for thermostatic radiator valve to Eindhoven Manufacturers, The product will supply to all over the world, such as: Slovenia , Congo , Guatemala , Our company is working by the operation principle of "integrity-based, cooperation created, people oriented, win-win cooperation". We hope we can have a friendly relationship with businessman from all over the world.
Assured Automation- We Make Automation Easy
Conversion of the O Series Pneumatic Actuator from Fail Closed to Fail Open
In this video we will be converting an O Series Fail Closed pneumatic actuator to Fail Open.
First remove the indicator cap from the top of the actuator.
Please note that the slot in the shaft is perpendicular tho the actuator housing . Remove spring end caps.
This is the actuator with the end caps fully removed.
To remove the internal pistons,place a wrench on the actuator stem and rotate counterclockwise until the pistons can be pulled out. It is very important to note the orientation of the pistons as they come out of the actuators, since you will rotate them 180°
Here is a side view showing how the piston was removed and how it engaged the internal yoke. The bar on the piston (A) engages with the notch in the yoke(B).
The shaft needs to be rotated so the piston engages on the opposite side. Use a wrench to rotate the shaft counterclockwise approximately 90 degrees.
After the pistons are rotated 180 degrees , push them into the actuator to engage with the yoke.
Rotate the shaft counterclockwise until the pistons are pulled fully into the actuator housing. Note the slot on the shaft should now be parallel to the actuator housing.
Re-attach the spring end caps but be sure to match the tabbed o-ring to mate with the air port on the actuator housing
Tighten end caps.
Attach indicator cap
The actuator should rotate clockwise when air is applied. It should spring closed counter clockwise when air is removed.
Assured Automation your source for automated valves and flow meter.
Assured Automation is a leading provider of automated valves and flow components for industrial process control applications. For over 20 years we have been providing state of the art automation to a diverse clientele ranging from small equipment manufacturers to Fortune 500 Manufacturing, Chemical and Pharmaceutical Companies.
Our product line consists of a complete offering of standardized automated valve assemblies with a variety of commonly used accessory items. In addition, we offer complete valve automation services where we supply special automated valve assemblies developed around your specified products or your particular applications. Full CAD capabilities are offered including AutoCAD, Solidworks or other commonly used design and drawing programs.
Our Goal is to make the selection, estimating and delivery of high quality automated valves and flow components as quick and easy as possible.
No heat or no A/C. Temperature control knob feels loose and is not controlling temperature control unit. Cable can come loose and needs to be reset on back of control panel. Honda Accord Civic Acura 1994 1995 1996 1997 heater air conditioning A/C is warm Freon valve air mixture freezing defrost blow smell knob easy fix Japanese Cars rice burner lx dx ex coupe wagon van repair manual Troubleshoot NO HEAT or A/C comes out Hot