Factory Cheap price TU-1A01 thermal wax actuator for thermostatic automatic water drain valve for Italy Importers

Factory Cheap price
 TU-1A01 thermal wax actuator for thermostatic automatic water drain valve for Italy Importers

Short Description:

Product Detail

Product Tags

As for competitive prices, we believe that you will be searching far and wide for anything that can beat us. We can state with absolute certainty that for such quality at such prices we are the lowest around for Thermostatic Faucet , Thermostat Radiator , Thermal Actuator Working , We warmly welcome small business companions from all walks of lifestyle, hope to establish friendly and cooperative business make contact with with you and attain a win-win objective.
Factory Cheap price TU-1A01 thermal wax actuator for thermostatic automatic water drain valve for Italy Importers Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.

 


Product detail pictures:

Factory Cheap price
 TU-1A01 thermal wax actuator for thermostatic automatic water drain valve for Italy Importers detail pictures


We usually perform being a tangible workforce making sure that we will give you the most beneficial excellent plus the finest selling price for Factory Cheap price TU-1A01 thermal wax actuator for thermostatic automatic water drain valve for Italy Importers, The product will supply to all over the world, such as: Suriname , Netherlands , Ukraine , We pursue the management tenet of "Quality is superior, Service is supreme, Reputation is first", and will sincerely create and share success with all clients. We welcome you to contact us for more information and look forward to working with you.



  • This project allows for manual and automatic temperature control of an aluminum block using a thermoelectric (TE) device. A high-side switch IC is used to turn on and off the device, while the direction of the current through the TE unit is controlled by a 12 V DPDT relay in an H-bridge configuration. This results in an ON/OFF temperature controller with the ability to switch between heating and cooling mode. Two LM35 temperature sensors monitor the ambient room temperature and aluminum block temperature.

    The LabVIEW program has both a manual and automatic mode. In manual mode, the current through the TE device is controlled with the “TE Current ON/OFF” and “Heat/Cool” buttons on the program’s front panel. In automatic mode, the program tries to maintain the temperature set point entered by the user. It accomplishes this by first determining whether it needs to heat or cool the block based on the difference between the set point and ambient room temperature. Once the program sets the correct current direction, it simply turns on and off the TE device via the high-side switch when it reaches the desired temperature.

    This video shows manual mode operation of the unit after 10 minutes in the “Cool” setting. You can see the ice on the aluminum block melt shortly after the program is set to “Heat”. In automatic mode, this setup is capable of achieving temperature control of ±0.5°C from set point.



    OMS, RCS, Fuel Cells, Auxiliary Power Unit and Hydraulic Systems

    View the complete course: https://ocw.mit.edu/16-885F05

    License: Creative Commons BY-NC-SA
    More information at https://ocw.mit.edu/terms
    More courses at https://ocw.mit.edu

    Send your message to us:

    INQUIRY NOW
    • * CAPTCHA: Please select the Truck

    Related Products

    INQUIRY NOW
    • * CAPTCHA: Please select the House

    WhatsApp Online Chat !