We believe in: Innovation is our soul and spirit. Quality is our life. Customer need is our God for Thermal Actuator Reliability , Electric Cylinder Actuator , Automatic Lcd Temperature Control Hair Brush Reviews , We are one of the largest 100% manufacturers in China. Many large trading companies import products from us, so we can give you the best price with the same quality if you are interested in us.
Best quality and factory TU-1H01 thermal wax actuator for industrial thermostatic water regulations mixing valve for South Africa Manufacturer Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.


Product detail pictures:

Best quality and factory
 TU-1H01 thermal wax actuator for industrial thermostatic water regulations mixing valve for South Africa Manufacturer detail pictures


High-quality comes 1st; assistance is foremost; business enterprise is cooperation" is our business enterprise philosophy which is constantly observed and pursued by our business for Best quality and factory TU-1H01 thermal wax actuator for industrial thermostatic water regulations mixing valve for South Africa Manufacturer, The product will supply to all over the world, such as: Brisbane , Nepal , Singapore , So far our products have been exported to east Europe, the Middle East, Southeast, Africa and South America etc. We have 13years professional sales and purchase in Isuzu parts at home and abroad and the ownership of the modernized electronic Isuzu parts checking systems. We honor our core principal of Honesty in business, priority in service and will do our best to offer our customers with high quality products and excellent service.



  • AUTOMATIC ROOM LIGHT CONTROLLER WITH BIDIRECTIONAL VISITOR COUNTER

    WHAT IS AUTOMATIC ROOM LIGHT CONTROLLER WITH BIDIRECTIONAL VISITOR COUNTER?
    Wastage of electricity is one of the main problems which we are facing now a days. In our home, school, colleges or industry we see that fan / lights are kept on even if there are nobody in the room or area / passage. This happens due to negligence or because we forgot to turn lights off or when we are in hurry. To avoid all such situations we have designed this project called “Automatic room light controller with bidirectional visitor counter”. This project has two modules, first one is known as “Bi-directional Visitor counter” and second module is known as “Automatic room light controller”. Main concept behind this project is known as “Visitor counter” which measures the number of persons entering in any room like seminar hall, conference room, classroom. This function is implemented using a pair of Infrared sensors. LCD display placed outside the room displays this value of person count. This person count will be incremented if somebody enters inside the room and at that time lights are turned on. And in reverse way, person count will be decremented if somebody leaves the room. When number of persons inside the room is zero, lights inside the room are turned off using a relay interface. In this way Relay does the operation of “Automatic room light controller”. Since this project uses 2 infrared sensors, it can be used as Bidirectional visitor counter as well.

    Designed and Developed By Rakesh Roy.

    Thanks and Regards,
    Robosoft Labs

    https://www.robosoftlabs.com

    https://www.robogeeks.in


    Send your message to us:

    INQUIRY NOW
    • * CAPTCHA: Please select the Flag

    Related Products

    INQUIRY NOW
    • * CAPTCHA: Please select the Heart

    WhatsApp Online Chat !