15 Years Manufacturer TU-1C01 thermal wax actuator for air conditioner and compressor for Chile Importers

15 Years Manufacturer
 TU-1C01 thermal wax actuator for air conditioner and compressor for Chile Importers

Short Description:

Product Detail

Product Tags

Our eternal pursuits are the attitude of "regard the market, regard the custom, regard the science" plus the theory of "quality the basic, have faith in the main and management the advanced" for Wax Vent Openers , Chrome Radiator Valves , Wholesale Paraffin Wax , Any interest, please feel free to contact us. We are looking forward to forming successful business relationships with new clients around the world in the near future.
15 Years Manufacturer TU-1C01 thermal wax actuator for air conditioner and compressor for Chile Importers Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.


Product detail pictures:

15 Years Manufacturer
 TU-1C01 thermal wax actuator for air conditioner and compressor for Chile Importers detail pictures


Sticking to your belief of "Creating solutions of high quality and generating buddies with people from all around the world", we always put the fascination of customers to start with for 15 Years Manufacturer TU-1C01 thermal wax actuator for air conditioner and compressor for Chile Importers, The product will supply to all over the world, such as: luzern , Lesotho , UAE , Our company's main products are widely used all over the world; 80% of our products exported to the United States, Japan, Europe and other markets. All stuff sincerely welcome guests come to visit our factory.



  • How to backup data – IAI SEL type Controller – Electric Actuator

    https://www.intelligentactuator.com/x-sel-pc-interface-software-tutorial/

    Connection Confirmation…
    Setting of Two or more Program…
    Controller – All Data Backup – Save File As, etc…
    – see details on the video —

    The XSEL PC Software is used with IAI’s fully programmable controller line. These controllers include the X-SEL, ASEL, PSEL, and SSEL as well as many older SEL controllers. The XSEL PC software is fully programmable and can perform many of the same functions as a small PLC.

    Establishing Communications

    The software may display the menu above when the X-SEL PC Interface software is started. Notice that a few of the menu options are unavailable. This is an indication that the software was unable to communicate with the controller (i.e. you are off-line). This may be due to the serial communication cable that is not secure to the PC and/or the X-SEL controller. Also make certain that the controller is ready to communicate by having the Teaching Serial Interface Port switch in the “‘MANU” position.

    Once communications has been established, all menus should become available as shown in the image above. To reestablish communications if accidentally lost, go to the ‘”Controller” menu and drop to “Reconnect”. The software will attempt to reestablish communication.

    Clearing Common Errors

    A possible error that may occur is the “EE6C-DO output current error”. This error is indicating that the digital IO card not being supplied 24VDC. In this case, it is important to check the wiring, polarity and 24V power supply to the controller as shown in the X-SEL Operation Manual. The error may also occur if the controller powers up before the 24VDC is applied to the controller. Once this error has occurred, it will persist until the controller is reset. The error will also be displayed on the 4-digit 7-segment display on the controller.

    Another error that may occur is the “ErG” error, that is indicated only the 4-digit 7-segment display of the controller. This error is simply e-stop. The X-SEL controller has a dedicated e-stop terminal at the System IO connector. This should be normally closed contact. While the controller is in Manu mode the e-stop connection of the Teaching/Communication Port becomes active. Also check the e-stop button of the IAI serial communication cable to release e-stop.

    Another error that may occur is the “ECA1- ABS Data Backup Battery Voltage Low Error (Driver)” error. This error is encountered on an X-SEL system equipped with absolute encoders. The following section will discuss this situation in greater detail.

    Homing

    The “ECA1″ error will be encountered on a X-SEL equipped with absolute encoders. This error is an alert that the absolute encoders have lost battery power resulting in a loss of positional information. The power loss may be due to a dead battery. In most cases, however, it is simply caused by disconnecting the encoder from the controller. The encoder battery is located on the controller for easy replacement. Once reconnected, the absolute encoders will have to be reset/homed to clear this error.
    Absolute Encoder Reset Menu
    Absolute Encoder Reset Menu

    The Absolute Encoder Reset Menu provided a quick and easy way to reset the encoders. To open this window go to the “Controller” menu and select “ABS. Encoder Reset”. At the top of the window, there is a drop-down menu that allows you to select the axis (1,2,3 or 4 depending on the system). Once an axis is selected simply click on the button indicated by the red arrow. As you progress the arrow will move next button indicating when the next step should be executed. Once all axis are reset go to the “Controller” menu and select “Software Reset”. This will reset the controller which completes the homing procedure.

    In the case of incremental encoders, the actuators would have to be homed every time that the controller powered up. This can be done with the “HOME” command in a program or it can be done through the point menu (see below). During e-stop the encoders maintain encoder power, making homing afterward unnecessary.

    Points

    The point table stores all positional information. The controller can store up to 3000 unique points. This menu will also provide servo control so that motors can be turned on, off, jog in both directions and move to taught positions on all selected axis or specific axis.

    Consider this window as a snapshot of what is stored on the controller. Anything that is typed on this window will not automatically be stored in the controller. The icon “Transmit to Controller” must be used to store the information in the controller. The prompt “Write to FLASH ROM?” asks the information should be stored in Flash ROM or RAM memory….



    A manifold is the hub of a heating system, and distributes water throughout a home. It provides a central place to connect both your supply and return lines. Supply water from the heat source enters the manifold and circulates hot water throughout the system. They can be used in radiant, hydronic, or snow-melt applications. SupplyHouse.com offers the manifolds in different sizes ranging from 2 to 12 loops.

    A heating manifold can be as simple as a copper unit with just supply and return ports with shut off valves for each. SupplyHouse.com also offers pre-assembled manifolds that come with some key accessories that you would normally buy separately.

    Shut off valves, temperature gauges, bleeders, flow meters and drain valves may be included depending on the brand you choose. Bleeders are used to release any air from the system when it is first filled with water and drain valves allow you to drain the system if needed. Temperature gauges make it easy to monitor the water temperature in your system. Shut off valves are used to close off either the supply or return ports if a repair is needed. Flow valves are used to ensure the heat is evenly distributed throughout a system and the flow meters give a visual indication of the water flow in each loop.

    Even when selecting a pre-assembled manifold, the accessories included vary by brand.

    If you want to use your manifold to heat multiple zones, you can purchase return side actuators. The actuators act as zone valves to allow you to use one manifold to control the temperature in different rooms independently.

    Heating manifolds generally require fittings with a specific thread made for that brand. You can not use standard pipe fittings found in stores.

    Each manifold system has a variety of adapters, end caps, and fitting assemblies that can be purchased to customize the manifold for different applications. SupplyHouse.com offers the individual manifolds as well as manifold kits that include the required fittings.

    Send your message to us:

    INQUIRY NOW
    • * CAPTCHA: Please select the Flag

    Related Products

    INQUIRY NOW
    • * CAPTCHA: Please select the Cup

    WhatsApp Online Chat !