13 Years Manufacturer TU-1C07 thermal wax actuator for air conditioner and compressor to Liberia Importers

13 Years Manufacturer
 TU-1C07 thermal wax actuator for air conditioner and compressor to Liberia Importers

Short Description:

Product Detail

Product Tags

We not only will try our greatest to offer superb companies to just about every buyer, but also are ready to receive any suggestion offered by our shoppers for Air Conditioner And Compressor , Automatic Temperature Control Washer , Thermal Analysis Of Actuator , We welcome all of the purchasers and pals to contact us for mutual added benefits. Hope to do additional business enterprise along with you.
13 Years Manufacturer TU-1C07 thermal wax actuator for air conditioner and compressor to Liberia Importers Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.

 


Product detail pictures:

13 Years Manufacturer
 TU-1C07 thermal wax actuator for air conditioner and compressor to Liberia Importers detail pictures


Along with the "Client-Oriented" small business philosophy, a rigorous high-quality handle system, highly developed producing machines and a powerful R&D group, we always supply high-quality products and solutions, fantastic services and aggressive costs for 13 Years Manufacturer TU-1C07 thermal wax actuator for air conditioner and compressor to Liberia Importers, The product will supply to all over the world, such as: US , San Diego , Lithuania , We have been persisting in the business essence "Quality First, Honoring Contracts and Standing by Reputations, providing customers with satisfying goods and service. " Friends both at home and abroad are warmly welcome to establish everlasting business relations with us.



  • In this video we explore the E46 M3 Automatic Climate Control option, and how to set this up. Don’t fight the system, embrace it. Most of these settings and system abilities are universal for most cars, so even if you drive an Audi, or a Fiat… You might learn something.

    special thanks to Obioban from M3forum for the information and direction on this topic. I figured I would make an easy to watch and understand video of his instructional article on the system. Hope I did your info justice Ian.



    ***VISIT OUR SPONSORS***
    https://www.traderadiators.com | https://www.grahamplumbersmerchant.co.uk | https://www.buteline.com/uk | https://www.adey.com

    This video covers thermostatic radiator valves. How they work and how you can install them. We also cover which room to install them and why.

    Today, we’re gonna look at thermostatic radiator valves otherwise known as TRVs. They individually control the temperature in the room to an individual radiator. Firstly, we’re gonna have a look at how to change them, and then we’re gonna have a look at how they work. I hope it’s very informative. Hold tight. So, how does a thermostatic radiator valve work, and what’s the difference between that and a normal radiator valve. Well, firstly, a normal radiator valve is just a valve that moves up and down and shuts off the flow of hot water from the boiler into the radiator, just like the tap on a bathtub. The main difference with a thermostatic radiator valve is that it automatically controls the amount of hot water going into a radiator according to the current heat of the room that it’s situated in. There are two main types of thermostatic radiator valve. One uses a spring that expands and contracts, and the other uses a wax jacket that does exactly the same. For this video, we’re gonna look at the spring type, because they both work in a very similar way. So, we have a spring that is made of metal that is very susceptible to the temperature around it. If the room is cold, the metal will be contracted because when metal is cold, it is contracted. Therefore, the valve jumper will be open and hot water will be allowed to flow into the radiator. If the room is warm, the spring will expand and that valve will be pushed down and the flow to the radiator will stop. And that’s how they work. A very common problem I have with customers is, sometimes they’ll come in, the room is cold, the radiator, when they feel it, blazing hot, and yet they still go to the thermostatic radiator valve and open it up more. That’s completely pointless. The room is cold, the radiator’s hot, therefore, the thermostatic radiator valve knows that the room is cold, and it’s trying to heat it up. If you go into a cold room and feel the radiator and it’s hot, do not touch the thermostatic radiator valve. Only touch it when you go into the room, and it’s cold, and you find that the radiator is cold. Also, another thing you need to consider, is where you can actually install thermostatic radiator valves. If you have house with two rooms, in one room you have the room thermostat, which controls the whole heating system, and one radiator. In the other room, you have another radiator and that has a TRV on it. Don’t put a TRV in the room that has the room thermostat in it. The reason for that is, if the TRV closes down, and the room thermostat is not satisfied, it will never knock the heating system off to the whole house, and you won’t get any saving. That room thermostat there needs to have an exactly true reading of the maximum capacity that the heating system can give out. Therefore, the radiator in the room with the room thermostat should have a lock shield on it that is fully open. So let’s go back to the house, and find out how you actually change a lock shield over for a TRV and really how easy they are to install. I’m assuming you all know how to drain down a heating system already. Finding the lowest point in the heating system and drain off, taking your hose outside and opening that up and making sure that the water supply is turned off to the heating system. Next, you allow air into all the radiators that you want to change in the TRVs. Generally, if you’re a bit worried about this, let air into every radiator in the house. You should hear the air sucking. As soon as you see your hose outside stop running, that should indicate that the heating system is drained down and you’re ready to change the valve. Let’s have a look here. As you can see, we’re removing this old lockshield valve here, which is just an on and off valve. So, now that we know the system is all drained down, we can loosen that off. Now’s the time just to make sure that the water has drained out of the system. As you can see it has. And then we can loosen off the 15mm pressure fitting on the bottom. As you can see, our new TRV isn’t going to fit on this current radiator insert. All new TRVs are supplied with a new insert, so this one here will need removing. There are special tools to do this. You can have a hexagonal tool that goes in like that, a square tool, a lug tool cut in here. This is quite an old one as you can see. Today I’m gonna use this one here because we’ve got hexagonal fitting on there. Now often you can just lift out and it may get out. But generally, you’ll have to just put the spanner on like this and then wind it out like that. There’s the old insert out, and that’s the old valve completely removed.

    Send your message to us:

    INQUIRY NOW
    • * CAPTCHA: Please select the House

    Related Products

    INQUIRY NOW
    • * CAPTCHA: Please select the Star

    WhatsApp Online Chat !