13 Years Manufacturer TU-1C02 thermal wax actuator for industrial adjustable temperature switch control for Bolivia Importers

13 Years Manufacturer
 TU-1C02 thermal wax actuator for industrial adjustable temperature switch control for Bolivia Importers

Short Description:

Product Detail

Product Tags

Persisting in "High top quality, Prompt Delivery, Aggressive Price", now we have established long-term cooperation with customers from the two overseas and domestically and get new and aged clients' large comments for Thermal Actuator Greenhouse , Wholesale Sensing Wax , Automation Temperature Control System , We are one of the largest 100% manufacturers in China. Many large trading companies import products from us, so we can give you the best price with the same quality if you are interested in us.
13 Years Manufacturer TU-1C02 thermal wax actuator for industrial adjustable temperature switch control for Bolivia Importers Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.


Product detail pictures:

13 Years Manufacturer
 TU-1C02 thermal wax actuator for industrial adjustable temperature switch control for Bolivia Importers detail pictures


Good quality To start with,and Purchaser Supreme is our guideline to offer the top service to our customers.Presently, we've been seeking our best to be amongst the top exporters inside our industry to fulfill consumers extra need to have for 13 Years Manufacturer TU-1C02 thermal wax actuator for industrial adjustable temperature switch control for Bolivia Importers, The product will supply to all over the world, such as: Finland , Slovakia , Jordan , With all these supports, we can serve every customer with quality product and timely shipping with highly responsibility. Being a young growing company, we might not the best, but we're trying our best to be your good partner.



  • A further, more detailed cleaning video can be found here https://www.youtube.com/watch?v=dkPuEmwP4oQ
    Although this is on a Volvo Euro3 163 D5, this valve is on millions of cars from many manufacturers.
    Improve turbo response and cure overboost with this simple fix.
    Boost before was 20 psi with uneven delivery.
    Boost after is 17 psi max with improved low down response.



    There are several troubleshoots the furnace sticker lists that might be the problem. I point out several of them. If you dont care to learn anything about the furnace and what sets off an error code 33, then just skip to 6:00 to see the fix. But for most people I think it would be helpful to watch the whole thing, (sure would have saved me a ton of time.) But now I know a lot about furnaces!

    #33 LIMIT CIRCUIT FAULT – Indicates a limit, draft safeguard, flame rollout, or blocked vent switch (if used) is open. Blower will run for 4 minutes or until open switch remakes whichever is longer. If longer than 3 minutes, code changes to lockout #13. If open less than 3 minutes status code #33 continues to flash until blower shuts off. Flame Rollout switch and BVSS require manual reset. Check for:
    - Restricted Vent
    - Proper Vent Sizing
    - Loose blower wheel
    - Excessive wind
    - Dirty filter or restricted duct system
    - Defective blower motor or capacitor
    - Defective switch or connections
    - Inadequate combustion air supply (flame rollout switch open)

    Bryant Heating and Cooling Systems
    Natural Gas
    Central Furnace
    Model Number 310AAV048135 / 310AAV048135ACJA
    Manufactured JUL 2006
    1/2 HP Motor

    Send your message to us:

    INQUIRY NOW
    • * CAPTCHA: Please select the Tree

    Related Products

    INQUIRY NOW
    • * CAPTCHA: Please select the Star

    WhatsApp Online Chat !