Wholesale price stable quality TU-028 thermostatic cartridge wax sensor for sanitary ware to Colombia Manufacturers

Wholesale price stable quality
 TU-028 thermostatic cartridge wax sensor for sanitary ware to Colombia Manufacturers

Short Description:

Product Detail

Product Tags

While using the "Client-Oriented" company philosophy, a demanding high-quality management method, innovative producing products and also a sturdy R&D workforce, we always deliver premium quality merchandise, superb solutions and aggressive selling prices for Automatic Lcd Temperature Control Hair Brush Reviews , Actuator Electric , Air Conditioner Part , Good quality, timely service and Competitive price, all win us a good fame in xxx field despite the international intense competition.
Wholesale price stable quality TU-028 thermostatic cartridge wax sensor for sanitary ware to Colombia Manufacturers Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.


Product detail pictures:

Wholesale price stable quality
 TU-028 thermostatic cartridge wax sensor for sanitary ware to Colombia Manufacturers detail pictures


We have probably the most state-of-the-art output equipment, experienced and qualified engineers and workers, recognized good quality manage systems plus a friendly skilled income workforce pre/after-sales support for Wholesale price stable quality TU-028 thermostatic cartridge wax sensor for sanitary ware to Colombia Manufacturers, The product will supply to all over the world, such as: Bolivia , Canada , Hungary , Our monthly output is more than 5000pcs. We have set up a strict quality control system. Please feel free to contact us for further information. We hope that we can establish long-term business relationships with you and carry out business on a mutually beneficial basis. We are and will be always trying our best to serve you.



  • Troubleshooting a Newmar RV slide-out which will not retract and how to do a temporary field repair to get you back on the road to a service center.



    Tutorial explaining how to replace the thermostat housing assembly, water pump and coolant drain and fill for an E46 series BMW. The specific video here is a 2002 330xi sedan that had a water pump that was beginning to weep coolant from the main shaft of the water pump. The video shows all the steps necessary to remove all related items on the engine and engine bay to access and properly remove and replace the cooling system components. The BMW parts department advised that I also change the thermostat housing assembly when doing the water pump because an old thermostat could risk failure without a moments notice. The thermostat and water pump and coolant were all purchased directly from BMW. Coolant was mixed using distilled water in a 60/40 solution mixed which I confirmed it’s freeze and boiling points using a widely available coolant tester made by Prestone. 1 4 litre jug of coolant or antifreeze (as some call it) can make up to a maximum of 8 litres of coolant mixed at a 50/50 to water ratio. I opted to make a 60/40 because in Canada our climate occasionally CAN dip to 34 degrees Celsius below 0.

    It is worth mentioning that doing a water pump replacement on a manual transmission based E46 is easier than one that has an automatic transmission because the cooling fan on the manual transmission 3 series BMWs use an electric cooling fan whereas the automatics use a hydraulically coupled fan clutch assembly that bolts onto the reverse threaded shaft of the water pump. IF you have an automatic transmission E46 then you will NEED to invest in a fan clutch holding tool specific to the E36 and E46 BMWs and a slim profile 32mm wrench to “reverse unscrew” the fan clutch off of the water pump. Not necessarily difficult to do BUT a little more work is involved plus the cost of buying the special tool. Everything else mentioned in this tutorial is otherwise the same.

    It is also advisable that since you’re removing everything out of the front of the engine that you replace both the serpentine drive belt and the a/c drive belt at the same time.

    The motor in my car is a 3.0 inline 6 cylinder M54B30 engine
    BMW Parts #’s

    11-51-7-527-910 (Water pump) replaces old part # BM11-51-7-503-884
    11-53-7-509-227 (Thermostat housing)
    83-51-9-415-964 (Engine coolant)

    Send your message to us:

    INQUIRY NOW
    • * CAPTCHA: Please select the Truck

    Related Products

    INQUIRY NOW
    • * CAPTCHA: Please select the Flag

    WhatsApp Online Chat !