1. Operation Principle
The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.
2. Characteristic
(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.
(2)Temperature control is reliable and nicety
(3)No shaking and tranquilization in working condition.
(4)The element doesn’t need special maintenance.
(5)Working life is long.
3.Main Technical Parameters
(1)Handspike’s height may be confirmed by drawing and technical parameters
(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.
(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.
(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.
(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.
Product detail pictures:
Our goal is usually to deliver high quality items at aggressive price ranges, and top-notch service to shoppers around the entire world. We're ISO9001, CE, and GS certified and strictly adhere to their high quality specifications for Wholesale Dealers of TU-1H01 thermal wax actuator for industrial thermostatic water regulations mixing valve for Afghanistan Manufacturers, The product will supply to all over the world, such as: Mexico , Morocco , Malawi , Our advanced equipment, excellent quality management, research and development ability make our price down. The price we offering may not be the lowest, but we guarantee it is absolutely competitive! Welcome to contact us immediately for future business relationship and mutual success!
Dielectric Elastomer Generators
Advantages:
• Supplementary, more environmentally-friendly and regenerative energy sources using new elastomer materials which converts mechanical energy of water flows in small rivers directly into electrical energy.
• The electrical energy is to be used for environmentally-friendly decentralized energy supply of e.g. camping sites, remote areas or for the recharge of electric vehicles in rural areas.
• The impact on landscapes, flow situations in rivers, restrictions of flora and fauna as well as on noise nuisance or very low.
Contact:
Dr. Bernhard Brunner
Neunerplatz 2
D- 97082 Wuerzburg
Phone +49 931 4100-416
bernhard.brunner@isc.fraunhofer.de
www.isc.fraunhofer.de; www.cesma.de
Code
#include 16f877a.h
#device adc=10 // Set ADC resolution to 10Bit
#fuses XT,NOLVP,NOWDT,NOPROTECT
#use delay(clock=4000000)
#use rs232(baud=9600,xmit=PIN_C6,rcv=PIN_C7,ERRORS)
#include “flex_lcd.c”
#define LOAD PIN_B7
#define THRES 30.0 // load switching threshold in Celsius
int16 digital_reading; // ADC resolution is 10Bit, an 8Bit integer is not enough to hold the reading
float temp;
void main()
/* ADC Initialization */
setup_adc(ADC_CLOCK_INTERNAL); // initialize ADC with a sampling rate of Crystal/4 MHz
setup_adc_ports(RA0_ANALOG); // set PIN_A0 as analog input channel
set_adc_channel(0); // point ADC to channel 0 for ADC reading
delay_ms(1); // ADC module is slow, needs some time to adjust.
/* Peripherals Configurations */
lcd_init(); // Turn LCD ON, along with other initialization commands
output_low(LOAD); // the load is initially OFF
lcd_gotoxy(1,1); // point LCD cursor to col1 row1
lcd_putc(“Temperature is:”); // print on LCD
while(1) // infinite loop
digital_reading = read_adc(); // capture current temperature reading
delay_us(100); // 0.1ms delay for ADC stabilization
temp = digital_reading * 0.4883; // convert reading to Celsius
lcd_gotoxy(1,2); // point LCD cursor to col1 row2
printf(lcd_putc,”%2.1f C”,temp); // print value on LCD
if(temp=THRES) output_high(LOAD); // Control Load
else output_low(LOAD);
delay_ms(1000); // 1 second delay between readings