Top Suppliers TU-1C02 thermal wax actuator for industrial adjustable temperature switch control Export to Kuala Lumpur

Top Suppliers
 TU-1C02 thermal wax actuator for industrial adjustable temperature switch control Export to Kuala Lumpur

Short Description:

Product Detail

Product Tags

Our company aims to operating faithfully, serving to all of our customers , and working in new technology and new machine constantly for Air Compressor Parts Filter , Air Compressor Pressure Switch , Automatic Hot Water Temperature Control Valves , Our enterprise insists on innovation to promote the sustainable advancement of organization, and make us become the domestic high-quality suppliers.
Top Suppliers TU-1C02 thermal wax actuator for industrial adjustable temperature switch control Export to Kuala Lumpur Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.


Product detail pictures:

Top Suppliers
 TU-1C02 thermal wax actuator for industrial adjustable temperature switch control Export to Kuala Lumpur detail pictures


With a positive and progressive attitude to customer's interest, our enterprise continually improves our products excellent to meet the wants of customers and further focuses on safety, reliability, environmental requirements, and innovation of Top Suppliers TU-1C02 thermal wax actuator for industrial adjustable temperature switch control Export to Kuala Lumpur, The product will supply to all over the world, such as: Russia , UK , Vietnam , Being the top solutions of our factory, our solutions series have been tested and won us experienced authority certifications. For additional parameters and item list details, be sure to click the button to acquire additional nformation.



  • Die City Solar AG ist ein deutsches Solarunternehmen mit Sitz in Bad Kreuznach, spezialisiert auf den Bau von Solargroßkraftwerken. Für den Messestand der Firma produziert Kontrastfilm einen Imagefilm. Der Film wird auf einem 103” Plasmabildschirm in den Messestand integriert.

    Time to think big! Das visuelle Konzept setzt zum einen auf animierte Typografie und zum anderen auf Zeitrafferaufnahmen.

    Drehbuch Daniel Seideneder
    Regie: Daniel Seideneder
    Kamera: Thomas Vollmar

    2008

    https://www.kontrastfilm.de/projekte/detail/dsa_dsa



    Carburetor Cleaning/Rebuildon 2013 Yamaha 20HP outboard 4-stroke.
    Problem: The motor would not idle properly.
    Diagnostic steps:
    1. Pull cord with throttle wide open to clear any excess fuel
    2. Pull cord with throttle cracked slightly while holding rag sprayed with starting fluid to the intake.
    3. The motor started at that point and it was determined the problem it was having was lack of fuel (using the rag with fluid offered an alternative source of fuel).
    4. Removed brass drain screw from side of carburetor, observed fuel running out indicating the bowl did have fuel supplied to it.

    Diagnosis:
    The carburetor did have fuel supplied to it but was failing to mix the fuel with the intake air due to a blockage inside the carburetor itself

    Remedy: Remove and clean carburetor fuel passages.

    For more helpful videos visit www.rowintel.com
    Contact us through the website with any question you have!

    Send your message to us:

    INQUIRY NOW
    • * CAPTCHA: Please select the Key

    Related Products

    INQUIRY NOW
    • * CAPTCHA: Please select the Tree

    WhatsApp Online Chat !