Leading Manufacturer for TU-028 thermostatic cartridge wax sensor for sanitary ware for Gabon Factory

Leading Manufacturer for
 TU-028 thermostatic cartridge wax sensor for sanitary ware for Gabon Factory

Short Description:

Product Detail

Product Tags

We keep on with our business spirit of "Quality, Performance, Innovation and Integrity". We goal to create much more worth for our customers with our rich resources, state-of-the-art machinery, experienced workers and exceptional providers for Temperature Wax , Energe Wax Manufacturers , Sensing Wax , Adhering to your small business principle of mutual positive aspects, we have now won superior popularity among our customers because of our best solutions, excellent products and competitive selling prices. We warmly welcome clients from your home and overseas to cooperate with us for common achievement.
Leading Manufacturer for TU-028 thermostatic cartridge wax sensor for sanitary ware for Gabon Factory Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.


Product detail pictures:

Leading Manufacturer for
 TU-028 thermostatic cartridge wax sensor for sanitary ware for Gabon Factory detail pictures


Together with the "Client-Oriented" enterprise philosophy, a arduous good quality control technique, sophisticated producing equipment and a sturdy R&D staff, we generally offer superior quality merchandise, superb solutions and aggressive rates for Leading Manufacturer for TU-028 thermostatic cartridge wax sensor for sanitary ware for Gabon Factory, The product will supply to all over the world, such as: Porto , Israel , Oslo , In order to meet more market demands and long-term development, a 150, 000-square-meter new factory is under construction, which will be put into use in 2014. Then, we shall own a large capacity of producing. Of course, we will continue improving the service system to meet the requirements of customers, bringing health, happiness and beauty to everyone.




  • “Design, development, and evaluation of an MRI-guided SMA spring-actuated neurosurgical robot”
    by Mingyen Ho, Yeongjin Kim, Shing Shin Cheng, Rao Gullapalli and Jaydev P. Desai

    International Journal of Robotics Research, 34(8): 1147-1163

    https://bit.ly/1pr2f0x

    ABSTRACT: In this paper, we present our work on the development of a magnetic resonance imaging (MRI)-compatible minimally invasive neurosurgical intracranial robot (MINIR) comprising shape memory alloy (SMA) spring actuators and tendon–sheath mechanisms. We present the detailed modeling and analysis along with experimental results of the characterization of SMA spring actuators. Furthermore, to demonstrate image-feedback control, we used the images obtained from a camera to control the motion of the robot so that eventually continuous MR images could be used in the future to control robot motion. Since the image tracking algorithm may fail in some situations, we also developed a temperature feedback control scheme which served as a backup controller for the robot. Experimental results demonstrated that both image feedback and temperature feedback can be used to control the motion of MINIR. A series of MRI compatibility tests was performed on the robot and the experimental results demonstrated that the robot is MRI-compatible and no significant visual image distortion was observed in the MR images during robot operation.

    Send your message to us:

    INQUIRY NOW
    • * CAPTCHA: Please select the Plane

    Related Products

    INQUIRY NOW
    • * CAPTCHA: Please select the Car

    WhatsApp Online Chat !