Hot-selling attractive price Thermostatic Wax Series for Italy Factory
Short Description:
Product Detail
Product Tags
Hot-selling attractive price Thermostatic Wax Series for Italy Factory Detail:
The characteristic of Thermostatic Wax consists of its volume expansion amount can reach up to 13 ~ 15 % when it is heated from solid to liquid. We use this characteristic, when it is heated to a solid-liquid transformation, its’ heat energy can translate into mechanical energy. Thermostatic Wax has been widely applied to temperature auto regulation of thermal-driving and various thermal-starting devices.
For example, automobile thermostat has been most widely well known, it has cylindrical seal part that loads some Thermostatic Waxes inside. To realize automatic temperature control, it was designed by a special technical specification for the solid-liquid transformation of Thermostatic Wax. When the cylindrical part is heated, Thermostatic Wax in the part is also heated and making a solid-liquid transformation expansion, Thermostatic Wax pushes thermostat’s itself handspike to open the valve. When the cylindrical part gets cold, Thermostatic Wax also cooled and start to shrink, Thermostatic Wax pushes itself handspike back to original situation under the return load force to close up the valve to realize automatic temperature control.
Depending on the main principle of Thermostatic Wax, The developed thermal driving devices and thermostats have been widely applied to automobile thermostat, automobile temperature-control switch for electric fan, various engines cooling water temperature auto controller, lubricant oil temperature auto control, auto cycle enriching valve, industry electric power control valve, water temperature regulating valve, safety device, space heating, fire protection, air filtering, temperature regulating device, sanitary ware and heating temperature controlling valve, air temperature control, ventilating control, solar water heater, automatic door and window, thermal driving electric switch, alarm apparatus, house ventilating, radiator temperature control valve, hot landing device for aviation and automaton etc.
Within temperature control range of –20 ~ 180 ℃ of Thermostatic Wax may compound with different temperature range and different efficient distance according to client’s technical demand. Our company may offer the relative technical service.
Model Number |
Appearance (Normal Temperature) |
Quality Standard |
|||
Range of Temperature Control |
Effective Distance Travel |
Water-Solubility Acid and Alkali |
Mechanical Impurity |
B100 |
Powder, Slice , Column |
90/100 |
≥10 |
Non. |
Non. |
B105 |
Powder, Slice , Column |
95/105 |
≥10 |
Non. |
Non. |
B110 |
Powder, Slice , Column |
100/110 |
≥10 |
Non. |
Non. |
B115 |
Powder, Slice , Column |
105/115 |
≥10 |
Non. |
Non. |
B120 |
Powder, Slice , Column |
110/120 |
≥10 |
Non. |
Non. |
B125 |
Powder, Slice , Column |
115/125 |
≥10 |
Non. |
Non. |
B130 |
Powder, Slice , Column |
120/130 |
≥10 |
Non. |
Non. |
B135 |
Powder, Slice , Column |
125/135 |
≥10 |
Non. |
Non. |
B140 |
Powder, Slice , Column |
130/140 |
≥10 |
Non. |
Non. |
B145 |
Powder, Slice , Column |
135/145 |
≥10 |
Non. |
Non. |
B150 |
Powder, Slice , Column |
140/150 |
≥10 |
Non. |
Non. |
B155 |
Powder, Slice , Column |
145/155 |
≥10 |
Non. |
Non. |
B160 |
Powder, Slice , Column |
150/160 |
≥10 |
Non. |
Non. |
B165 |
Powder, Slice , Column |
155/165 |
≥10 |
Non. |
Non. |
B170 |
Powder, Slice , Column |
160/170 |
≥10 |
Non. |
Non. |
B175 |
Powder, Slice , Column |
165/175 |
≥10 |
Non. |
Non. |
B180 |
Powder, Slice , Column |
170/180 |
≥10 |
Non. |
Non |
Product detail pictures:

We're proud from the higher client fulfillment and wide acceptance due to our persistent pursuit of high quality both on product and service for Hot-selling attractive price Thermostatic Wax Series for Italy Factory, The product will supply to all over the world, such as: Nicaragua , Sudan , Bulgaria , Further, we are supported by highly experienced and knowledgeable professionals, who have immense expertise in their respective domain. These professionals work in close coordination with each other to offer our clients an effective range of products.
How to backup data – IAI SEL type Controller – Electric Actuator
https://www.intelligentactuator.com/x-sel-pc-interface-software-tutorial/
Connection Confirmation…
Setting of Two or more Program…
Controller – All Data Backup – Save File As, etc…
– see details on the video —
The XSEL PC Software is used with IAI’s fully programmable controller line. These controllers include the X-SEL, ASEL, PSEL, and SSEL as well as many older SEL controllers. The XSEL PC software is fully programmable and can perform many of the same functions as a small PLC.
Establishing Communications
The software may display the menu above when the X-SEL PC Interface software is started. Notice that a few of the menu options are unavailable. This is an indication that the software was unable to communicate with the controller (i.e. you are off-line). This may be due to the serial communication cable that is not secure to the PC and/or the X-SEL controller. Also make certain that the controller is ready to communicate by having the Teaching Serial Interface Port switch in the “‘MANU” position.
Once communications has been established, all menus should become available as shown in the image above. To reestablish communications if accidentally lost, go to the ‘”Controller” menu and drop to “Reconnect”. The software will attempt to reestablish communication.
Clearing Common Errors
A possible error that may occur is the “EE6C-DO output current error”. This error is indicating that the digital IO card not being supplied 24VDC. In this case, it is important to check the wiring, polarity and 24V power supply to the controller as shown in the X-SEL Operation Manual. The error may also occur if the controller powers up before the 24VDC is applied to the controller. Once this error has occurred, it will persist until the controller is reset. The error will also be displayed on the 4-digit 7-segment display on the controller.
Another error that may occur is the “ErG” error, that is indicated only the 4-digit 7-segment display of the controller. This error is simply e-stop. The X-SEL controller has a dedicated e-stop terminal at the System IO connector. This should be normally closed contact. While the controller is in Manu mode the e-stop connection of the Teaching/Communication Port becomes active. Also check the e-stop button of the IAI serial communication cable to release e-stop.
Another error that may occur is the “ECA1- ABS Data Backup Battery Voltage Low Error (Driver)” error. This error is encountered on an X-SEL system equipped with absolute encoders. The following section will discuss this situation in greater detail.
Homing
The “ECA1″ error will be encountered on a X-SEL equipped with absolute encoders. This error is an alert that the absolute encoders have lost battery power resulting in a loss of positional information. The power loss may be due to a dead battery. In most cases, however, it is simply caused by disconnecting the encoder from the controller. The encoder battery is located on the controller for easy replacement. Once reconnected, the absolute encoders will have to be reset/homed to clear this error.
Absolute Encoder Reset Menu
Absolute Encoder Reset Menu
The Absolute Encoder Reset Menu provided a quick and easy way to reset the encoders. To open this window go to the “Controller” menu and select “ABS. Encoder Reset”. At the top of the window, there is a drop-down menu that allows you to select the axis (1,2,3 or 4 depending on the system). Once an axis is selected simply click on the button indicated by the red arrow. As you progress the arrow will move next button indicating when the next step should be executed. Once all axis are reset go to the “Controller” menu and select “Software Reset”. This will reset the controller which completes the homing procedure.
In the case of incremental encoders, the actuators would have to be homed every time that the controller powered up. This can be done with the “HOME” command in a program or it can be done through the point menu (see below). During e-stop the encoders maintain encoder power, making homing afterward unnecessary.
Points
The point table stores all positional information. The controller can store up to 3000 unique points. This menu will also provide servo control so that motors can be turned on, off, jog in both directions and move to taught positions on all selected axis or specific axis.
Consider this window as a snapshot of what is stored on the controller. Anything that is typed on this window will not automatically be stored in the controller. The icon “Transmit to Controller” must be used to store the information in the controller. The prompt “Write to FLASH ROM?” asks the information should be stored in Flash ROM or RAM memory….
Watch a better version here: https://youtu.be/d8jNWN6TRzE
AC Gears 0:17
Support DarkDragonWing by bookmarking these links and start shopping:
eBay https://goo.gl/OuDFKV
Amazon https://amzn.to/2osexVv
——————————
This is a blue 2003 Mitsubishi Lancer ES 2.0L 4G94 SOHC AUTO FWD. I’m cleaning it up from the bottom, hoping to make it look nice and in a good condition.
——————————
Lancer A/C Heater Control Gears 7801A110
eBay https://goo.gl/ayZzW9
Amazon https://amzn.to/2n8Tw6f
——————————
Most Mitsubishi Lancers have this same problem with the A/C Heater gears/knob control.
1. Changing the gears. “GENUINE heater air controller” Search it on eBay.com
——————————
Mods on this car:
*Red calipers, red drums
*Security alarm CrimeStopper SP-400 with the engine start system
*Trunk release kit
*GENUINE A/C heater air controller gears kit
——————————
DKDGWi Facebook Page: https://goo.gl/UvpnWC
DKDGWi Store: https://goo.gl/4hIzKm
DKDGWi Thingiverse: https://goo.gl/1eJPhi
DKDGWi Patreon: https://goo.gl/grJfLw
Mackey Facebook Page: https://goo.gl/9hMiSD
Mackey Twitter: https://goo.gl/Prl4ri
——————————
Video By:
Krissana Mingkwan Mackey – กฤษณะ มิ่งขวัญ แม็กกี้
Thaweesak Mingkwan Manny – ทวีศักดิ์ มิ่งขวัญ แมนนี่