High Quality Industrial Factory TU-1H05 thermal wax actuator for thermostatic radiator valve Wholesale to Denver
Short Description:
Product Detail
Product Tags
High Quality Industrial Factory TU-1H05 thermal wax actuator for thermostatic radiator valve Wholesale to Denver Detail:
1. Operation Principle
The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.
2. Characteristic
(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.
(2)Temperature control is reliable and nicety
(3)No shaking and tranquilization in working condition.
(4)The element doesn’t need special maintenance.
(5)Working life is long.
3.Main Technical Parameters
(1)Handspike’s height may be confirmed by drawing and technical parameters
(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.
(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.
(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.
(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.
Product detail pictures:
Our company insists all along the quality policy of "product quality is base of enterprise survival; customer satisfaction is the staring point and ending of an enterprise; persistent improvement is eternal pursuit of staff" and the consistent purpose of "reputation first, customer first" for High Quality Industrial Factory TU-1H05 thermal wax actuator for thermostatic radiator valve Wholesale to Denver, The product will supply to all over the world, such as: Naples , Niger , New Zealand , With a team of experienced and knowledgeable personnel, our market covers South America, the USA, the Mid East, and North Africa. Many customers have become our friends after good cooperation with us. If you have the requirement for any of our products, please contact us now. We are looking forward to hearing from you soon.
In this video, I have a 98 chevy pickup with a coolant temp gauge that started to read lower then normal. The problem that a lot of folks run into is that there are two temperature sensors in this engine. This also applies to the same era tahoes and suburbans with the 5.7 liter engine.
I test the temp gauge itself to rule out the gauge as being the problem. If the gauge itself has an internal problem that won’t let it go past 1/4 of the way up, then replacing the sensor would be a waste of time and money. In a future video I will replace the sensor and we’ll see if it’s fixed.
Thanks for watching and if you have one of these trucks be sure to subscribe for more!
Due to the number of internet technicians out there, comments and likes are disabled. I’m a busy guy and don’t have time to argue with trolls about what they didn’t like or what they would have done different. Thanks for the views though!
https://www.kep.ua/en/device/106/hvts-70-50/
High Voltage Test System HVTS-70/50 perform DC high-voltage testing of power cables (IEC 60502-2) up to 70 kV, power cables accessories (IEC 61442) as well as AC high-voltage testing, up to 50 kV at 50 Hz, of switchgear, reclosers, dielectric insulators, highvoltage dischargers (arresters), busbars and other dielectric materials with relatively low electric capacitance.
Main advantages
HVTS-70/50 is portable equipment. The control unit is enclosed in high-impact plastic case with a handy strap.
Test system HVTS-70/50 is:
- Supplies the high voltage test on the object and control of leakage current;
- Ensures high accuracy and maintenance of the test voltage at a certain level, it is possible to adjust the leakage current with an external capacitor additional DC voltage during the test;
- Measures the voltage directly at the load, allowing you to have a real idea about the stress tests on the object and control it with the specified accuracy. In addition, significantly increasing the safety of the staff, especially when removing the residual capacitive charge when disconnecting the high voltage;
- Made in a sealed enclosure provides protection for remote control from dust and moisture, which is especially important when using the machine in the field;
- Equipped with a modern system of removal of residual capacitive charge using the secondary winding of the transformer and has an optional external shorting;
- A protection scheme on excess input and output current limit and set the output voltage exceeds the set. HVTS-70/50 has the ability to program required for a particular test value of the maximum current and maximum voltage protection circuitry;
- High voltage unit has a built-in pressure sensors and temperature sulfur hexafluoride transformer with output of their state on the graphic display;
- The ability to save the settings of the eight most commonly performed types of testing (insulators, surge protectors, switches, cables, 6.3 kV, 10 kV cables, etc.);
- Display all the necessary information on the specifications and test results on a graphical display. During the test, shows the numerical values of the test voltage (rms), test current (rms) and the timer duration of the test. Additionally displays the voltage (amplitude), the shape factor for AC voltage or crest factor for the rectified voltage. An estimation of the dynamics of changes in the test parameters displayed a linear scale display of voltage and current;
- A choice between manual and automatic operation. The latter involves the installation of the operator values of the test voltage in steps of 0.1 kV, lifting speed of the test voltage, the voltage test current protection operation time of the test;
- Preservation of the non-volatile memory of archival records of tests carried out with information about the time of the test, the averaged voltage at the facility and the leakage current;
- The ability to work remotely – reading the archived data on the tests carried out, the setting and the choice of test parameters, workflow management