Factory wholesale Thermostatic Wax Series for Philippines Importers
Short Description:
Product Detail
Product Tags
Factory wholesale Thermostatic Wax Series for Philippines Importers Detail:
The characteristic of Thermostatic Wax consists of its volume expansion amount can reach up to 13 ~ 15 % when it is heated from solid to liquid. We use this characteristic, when it is heated to a solid-liquid transformation, its’ heat energy can translate into mechanical energy. Thermostatic Wax has been widely applied to temperature auto regulation of thermal-driving and various thermal-starting devices.
For example, automobile thermostat has been most widely well known, it has cylindrical seal part that loads some Thermostatic Waxes inside. To realize automatic temperature control, it was designed by a special technical specification for the solid-liquid transformation of Thermostatic Wax. When the cylindrical part is heated, Thermostatic Wax in the part is also heated and making a solid-liquid transformation expansion, Thermostatic Wax pushes thermostat’s itself handspike to open the valve. When the cylindrical part gets cold, Thermostatic Wax also cooled and start to shrink, Thermostatic Wax pushes itself handspike back to original situation under the return load force to close up the valve to realize automatic temperature control.
Depending on the main principle of Thermostatic Wax, The developed thermal driving devices and thermostats have been widely applied to automobile thermostat, automobile temperature-control switch for electric fan, various engines cooling water temperature auto controller, lubricant oil temperature auto control, auto cycle enriching valve, industry electric power control valve, water temperature regulating valve, safety device, space heating, fire protection, air filtering, temperature regulating device, sanitary ware and heating temperature controlling valve, air temperature control, ventilating control, solar water heater, automatic door and window, thermal driving electric switch, alarm apparatus, house ventilating, radiator temperature control valve, hot landing device for aviation and automaton etc.
Within temperature control range of –20 ~ 180 ℃ of Thermostatic Wax may compound with different temperature range and different efficient distance according to client’s technical demand. Our company may offer the relative technical service.
Model Number |
Appearance (Normal Temperature) |
Quality Standard |
|||
Range of Temperature Control |
Effective Distance Travel |
Water-Solubility Acid and Alkali |
Mechanical Impurity |
B100 |
Powder, Slice , Column |
90/100 |
≥10 |
Non. |
Non. |
B105 |
Powder, Slice , Column |
95/105 |
≥10 |
Non. |
Non. |
B110 |
Powder, Slice , Column |
100/110 |
≥10 |
Non. |
Non. |
B115 |
Powder, Slice , Column |
105/115 |
≥10 |
Non. |
Non. |
B120 |
Powder, Slice , Column |
110/120 |
≥10 |
Non. |
Non. |
B125 |
Powder, Slice , Column |
115/125 |
≥10 |
Non. |
Non. |
B130 |
Powder, Slice , Column |
120/130 |
≥10 |
Non. |
Non. |
B135 |
Powder, Slice , Column |
125/135 |
≥10 |
Non. |
Non. |
B140 |
Powder, Slice , Column |
130/140 |
≥10 |
Non. |
Non. |
B145 |
Powder, Slice , Column |
135/145 |
≥10 |
Non. |
Non. |
B150 |
Powder, Slice , Column |
140/150 |
≥10 |
Non. |
Non. |
B155 |
Powder, Slice , Column |
145/155 |
≥10 |
Non. |
Non. |
B160 |
Powder, Slice , Column |
150/160 |
≥10 |
Non. |
Non. |
B165 |
Powder, Slice , Column |
155/165 |
≥10 |
Non. |
Non. |
B170 |
Powder, Slice , Column |
160/170 |
≥10 |
Non. |
Non. |
B175 |
Powder, Slice , Column |
165/175 |
≥10 |
Non. |
Non. |
B180 |
Powder, Slice , Column |
170/180 |
≥10 |
Non. |
Non |
Product detail pictures:
As for competitive prices, we believe that you will be searching far and wide for anything that can beat us. We can state with absolute certainty that for such quality at such prices we are the lowest around for Factory wholesale Thermostatic Wax Series for Philippines Importers, The product will supply to all over the world, such as: United Kingdom , Gabon , venezuela , "Create Values,Serving Customer!" is the aim we pursue. We sincerely hope that all customers will establish long term and mutually beneficial cooperation with us.If you wish to get more details about our company, You should contact with us now!
How To Use A Mitsubishi Air Conditioner Remote Control Guide
https://www.rfohl.com/
(610) 377-1098
Mitsubishi split unit heating and cooling systems are a great way to keep the inside of your home or office comfortable all year round. These HVAC systems come with remote controls for setting the temperature and controlling the system. This video discusses the remote control.
For more information or to see a ductless split unit system, please visit our showroom.
R.F. Ohl
400 Interchange Rd
Lehighton, PA 18235
(610) 377-1098
Visit us on Facebook: https://www.facebook.com/rf.ohlfuel
Visit us on Twitter: https://twitter.com/RF_Ohl
Watch our other YouTube Videos: https://www.youtube.com/channel/UC3yXwPjcmP5xHidivNff_Ag
Handling of the remote controller unit for your Mitsubishi A/C
• The range that the signal can reach is about 6 m when the remote controller is pointed at the front of the indoor unit.
• When a button is pressed, one or two beeps will be heard from the indoor unit. If no sound is heard, operate again.
• Use the remote controller carefully. If it is dropped, thrown or it gets wet, the remote controller may not operate.
When installing the remote controller on a wall, etc.
• Install the remote controller holder in a position where the signal reception sound (beep) can be heard from the indoor unit when the ON/OFF button is pressed.
How to set the batteries and the current time in the Mitsubishi remote control device for your air conditioning system:
1- Remove the front lid and insert batteries, then reattach the front lid. Insert the minus pole of the batteries first. Check if the polarity of the batteries is correct.
2- Press the RESET button. If the RESET button is not pressed, the remote controller may not operate correctly.
3- Press the CLOCK set button.
4- Press the HR. and MIN. buttons (TIME SET buttons) to set the current time. Each time the HR button is pressed, the set time
increases by 1 hour, and each time the MIN button is pressed, the set time increases by 1 minute.
5- Press the CLOCK set button again and close the front lid.
When the remote controller cannot be used (emergency operation)
When the batteries of the remote controller run out or the remote controller malfunctions, the emergency operation can be done using the EMERGENCY OPERATION switch.
Press the EMERGENCY OPERATION switch.
• Each time the EMERGENCY OPERATION switch is pressed, the unit will operate in order of EMERGENCY COOL MODE, EMERGENCY HEAT MODE and STOP MODE. However, when the EMERGENCY OPERATION switch is once pressed, the unit will operate in test run for 30 minutes and then the operation mode shifts to EMERGENCY MODE.
To stop the emergency operation, press the EMERGENCY OPERATION switch once (in case of EMERGENCY HEAT MODE) or twice (in case of EMERGENCY COOL MODE).
Related Search Phrases:
Mitsubishi remote control air conditioner instructions
Mitsubishi electric air conditioner remote control manual
Mitsubishi air conditioner remote control replacement
Mitsubishi air conditioner remote control app
Mitsubishi air conditioner remote control symbols
Mitsubishi inverter air conditioner remote controller manual
how to use Mitsubishi air conditioner remote control
Mitsubishi ac remote control
Mitsubishi air conditioner remote control code
John Roberts Nissan 2747 Hillsboro Blvd in Manchester, TN 37355 Learn More: …