We persistently execute our spirit of ''Innovation bringing growth, Highly-quality making sure subsistence, Administration marketing reward, Credit history attracting clients for Thermal Actuator Manufacturer , Brass Faucet Valve Ceramic Cartridge , Thermal Actuator Efficiency , To better expand market, we sincerely invite ambitious individuals and companies to join as an agent.
Factory source manufacturing TU-3A01 thermal wax actuator for air conditioner and compressor Export to The Swiss Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.


Product detail pictures:

Factory source manufacturing
 TU-3A01 thermal wax actuator for air conditioner and compressor Export to The Swiss detail pictures


We continuously execute our spirit of ''Innovation bringing development, Highly-quality ensuring subsistence, Management advertising and marketing gain, Credit history attracting buyers for Factory source manufacturing TU-3A01 thermal wax actuator for air conditioner and compressor Export to The Swiss, The product will supply to all over the world, such as: Irish , Luxembourg , Moldova , As a way to use the resource on the expanding info in international trade, we welcome prospects from everywhere on the web and offline. In spite on the high quality objects we offer you, effective and satisfying consultation service is supplied by our qualified after-sale service group. Item lists and in depth parameters and any other info weil be sent to you timely for the inquiries. So you should make contact with us by sending us emails or call us when you've got any questions about our organization. ou could also get our address information from our site and come to our enterprise. We get a field survey of our merchandise. We're confident that we are going to share mutual accomplishment and create solid co-operation relations with our companions within this market place. We're seeking forward for your inquiries.



  • How to retrieve and read the fault codes from a dual zone climate control system..Mercedes w208,….w203 is the same and w210 is similar..
    THE CODES ARE LISTED BELOW
    The # in brackets following the code is the location # of the faulty part..the following website shows the location for those parts.

    https://w208.info/repair/electric

    226 – In-car temperature sensor (B10/4)
    227 – Outside temperature indicator temperature sensor (B14)
    228 – Heater core temperature (B10/1)
    229 – Heater core temperature (B10/1)
    230 – Evaporator temperature sensor (B10/6)
    231 – ECT sensor (B11/4)
    232 – Refrigerant pressure sensor (B12)
    233 – Refrigerant temperature sensor (B12/1)
    234 – Sun sensor (B32)
    235 – Emissions sensor (B31)
    241 – Refrigerant fill
    416 – Coolant circulation pump (M13)
    417 – Duovalve (Y21y1), left
    418 – Duovalve (Y21y2), right
    419 – Electromagnetic clutch (A9k1)
    420 – Idle speed increase
    421 – Pulse module (N65)
    422 – Series interface (K1) connection to instrument cluster (A1)
    423 – Switchover valve block (Y11)
    424 – Activated charcoal filter actuator (A32m2) open
    425 – Activated charcoal filter actuator (A32m2) closed
    432 – Non-USA DTC
    459 – Series interface (K2) connection to instrument cluster (A1)
    462 – Wide open throttle (WOT) position signal