factory customized TU-1D091 thermal wax actuator for industrial thermostatic water regulations mixing valve for Lahore Importers

factory customized
 TU-1D091 thermal wax actuator for industrial thermostatic water regulations mixing valve for Lahore Importers

Short Description:

Product Detail

Product Tags

The corporation upholds the philosophy of "Be No.1 in high quality, be rooted on credit rating and trustworthiness for growth", will continue to serve outdated and new consumers from home and overseas whole-heatedly for Screw Air Compressor Parts , Industrial Wax Factory , Automatic Temperature Control Washer , Sincerely hope we are growing up together with our prospects all over the environment.
factory customized TU-1D091 thermal wax actuator for industrial thermostatic water regulations mixing valve for Lahore Importers Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.


Product detail pictures:

factory customized
 TU-1D091 thermal wax actuator for industrial thermostatic water regulations mixing valve for Lahore Importers detail pictures


We also offer product sourcing and flight consolidation services. We have our own factory and sourcing office. We can provide you with almost every type of product related to our product range for factory customized TU-1D091 thermal wax actuator for industrial thermostatic water regulations mixing valve for Lahore Importers, The product will supply to all over the world, such as: Kuwait , Tanzania , South Korea , We rely on high-quality materials, perfect design, excellent customer service and the competitive price to win the trust of many customers at home and abroad. 95%products are exported to overseas markets.



  • This video is in Urdu Language I you want to watch in English language you can contact me .
    Temperature Monitoring And Control System Using AVR micro controller(Atmega32) and LM35 .
    Project Details will be provide on request .



    Watch as Dan from our product support team unboxes an eight loop Bluefin manifold.

    Compatible with Rifeng accessories and replacement parts.

    Includes supply/return shut-off valves with temperature wells.

    Requires 16 Loop Fitting Assemblies (please see below).

    Bleeder valves that come equipped with Bluefin Manifolds are 1″ BSP Thread (manifold inlet) x 3/4″ BSP Thread (outlet). If your application requires you to connect to a garden hose, you will need to purchase a Mr. PEX Manifold End Cap w/ Swivel Fill-Drain Valve separately which is 1″ BSP x 3/4″ Hose Thread

    Features:

    Flexible, modular and singular design system
    Easy-to-assemble construction
    Precise flow control and balancing
    Fitting for both PEX and Multilayer Pipe
    Control for the dominant heating systems like hydronic floor heating, fan coil heating or baseboard heating.
    No Sealant or Teflon required
    This manifold requires (16) Loop Fitting Assemblies:

    PEX Loop Fitting Assemblies Options

    1/2″ PEX to EK20 Loop Fitting Assembly
    This fitting will connect 1/2″ PEX to a loop of the Manifold
    3/8″ PEX to EK20 Loop Fitting Assembly
    This fitting will connect 3/8″ PEX to a loop of the Manifold
    5/8″ PEX to EK20 Loop Fitting Assembly
    This fitting will connect 5/8″ PEX to a loop of the Manifold

    PEX-AL-PEX Loop Fitting Assemblies Options

    MA-50PAP: 1/2″ PEX-AL-PEX to EK20 Loop Fitting Assembly
    This fitting will connect 1/2″ PEX-AL-PEX to a loop of the Manifold
    3/8″ PEX-AL-PEX to EK20 Loop Fitting Assembly
    This fitting will connect 3/8″ PEX-AL-PEX to a loop of the Manifold
    MA-58PAP: 5/8″ PEX-AL-PEX to EK20 Loop Fitting Assembly
    This fitting will connect 5/8″ PEX-AL-PEX to a loop of the Manifold

    Optional Installation Accessories:

    Loop End Cap

    3610003: Manifold Loop End Cap
    These allow you to cap off a loop of the manifold if it will not be used.

    Actuators

    Thermal Actuator for Bluefin Manifolds

    If you want to use your manifold to heat multiple zones, you can purchase return side actuators that work along side thermostats. The actuators act as zone valves to allow you to use one manifold to control the temperature in different rooms independently.

    Supply/Return Adapter Options

    MA-1014C: Supply/Return Adapter to 1″ & 1-1/4″ Copper
    MA-10MPT: Supply/Return Adapter to 1″ Male NPT
    MA-10FPT: Supply/Return Adapter to 1″ Female NPT
    MA-75MPT: Supply/Return Adapter to 3/4″ Male NPT