Factory Cheap Hot TU-1C03 thermal wax actuator for industrial adjustable temperature switch control to Serbia Manufacturers

Factory Cheap Hot
 TU-1C03 thermal wax actuator for industrial adjustable temperature switch control to Serbia Manufacturers

Short Description:

Product Detail

Product Tags

With reliable quality process, good reputation and perfect customer service, the series of products produced by our company are exported to many countries and regions for Air Conditioner And Compressor , Wax Actuator Manufacturers , Lg Ac Parts , Leading the trend of this field is our persistent goal. Providing first class products is our aim. To create a beautiful future, we would like to cooperate with all friends at home and abroad. Should you have any interest in our products, please do not hesitate to contact us.
Factory Cheap Hot TU-1C03 thermal wax actuator for industrial adjustable temperature switch control to Serbia Manufacturers Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.

 


Product detail pictures:

Factory Cheap Hot
 TU-1C03 thermal wax actuator for industrial adjustable temperature switch control to Serbia Manufacturers detail pictures


We goal to understand excellent disfigurement from the manufacturing and supply the top support to domestic and abroad clients wholeheartedly for Factory Cheap Hot TU-1C03 thermal wax actuator for industrial adjustable temperature switch control to Serbia Manufacturers, The product will supply to all over the world, such as: Sierra Leone , Florida , Hungary , Our market share of our products and solutions has greatly increased yearly. If you are interested in any of our products or would like to discuss a custom order, make sure you feel free to contact us. We've been looking forward to forming successful business relationships with new clients around the world in the near future. We've been looking forward to your inquiry and order.



  • There are several troubleshoots the furnace sticker lists that might be the problem. I point out several of them. If you dont care to learn anything about the furnace and what sets off an error code 33, then just skip to 6:00 to see the fix. But for most people I think it would be helpful to watch the whole thing, (sure would have saved me a ton of time.) But now I know a lot about furnaces!

    #33 LIMIT CIRCUIT FAULT – Indicates a limit, draft safeguard, flame rollout, or blocked vent switch (if used) is open. Blower will run for 4 minutes or until open switch remakes whichever is longer. If longer than 3 minutes, code changes to lockout #13. If open less than 3 minutes status code #33 continues to flash until blower shuts off. Flame Rollout switch and BVSS require manual reset. Check for:
    - Restricted Vent
    - Proper Vent Sizing
    - Loose blower wheel
    - Excessive wind
    - Dirty filter or restricted duct system
    - Defective blower motor or capacitor
    - Defective switch or connections
    - Inadequate combustion air supply (flame rollout switch open)

    Bryant Heating and Cooling Systems
    Natural Gas
    Central Furnace
    Model Number 310AAV048135 / 310AAV048135ACJA
    Manufactured JUL 2006
    1/2 HP Motor



    If your oven temperature is not consitent it may be the oven temperature probe. This video will walk you thru testing and replacing.

    Send your message to us:

    INQUIRY NOW
    • * CAPTCHA: Please select the Plane

    Related Products

    INQUIRY NOW
    • * CAPTCHA: Please select the Cup

    WhatsApp Online Chat !