China Professional Supplier TU-1J02 thermal wax actuator for electric switch valve Export to kazan

China Professional Supplier
 TU-1J02 thermal wax actuator for electric switch valve Export to kazan

Short Description:

Product Detail

Product Tags

"Sincerity, Innovation, Rigorousness, and Efficiency" may be the persistent conception of our organization for that long-term to establish jointly with customers for mutual reciprocity and mutual gain for Tool Shop Air Compressor Parts , Electric Actuator Control Valve , Radiator Thermostat , Welcome all customers of home and abroad to visit our company, to forge a brilliant future by our cooperation.
China Professional Supplier TU-1J02 thermal wax actuator for electric switch valve Export to kazan Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.


Product detail pictures:

China Professional Supplier
 TU-1J02 thermal wax actuator for electric switch valve Export to kazan detail pictures


Gaining purchaser gratification is our company's aim eternally. We're going to make great initiatives to create new and top-quality products, satisfy your exclusive prerequisites and supply you with pre-sale, on-sale and after-sale solutions for China Professional Supplier TU-1J02 thermal wax actuator for electric switch valve Export to kazan, The product will supply to all over the world, such as: Finland , Lithuania , Turin , With nearly 30 years' experience in business, we are confident in superior service, quality and delivery. We warmly welcome customers from all over the world to cooperate with our company for common development.



  • This is a circuit that uses a thermistor to turn on a fan when a certain temperature is exceeded. This video contains the actual testing of the circuit, the components list, and the schematic diagram of the circuit. We used this as part of our project which also included a heating system which turns on when it goes below a certain temperature and it comes with an LCD to display the current temperature of the room.
    -comment your email add if you need help to make this, i can send you my project document. :)



    Mercedes single zone climate control trouble code readout,and reset procedure..Many Mercedes models used this same climate control panel…look closely to be sure yours is the same…dual zone climate controls have a different procedure and some specific codes..r129,w210,w124,w202,w140 and others, all can possibly have this panel as standard equipment depending on which country and what equipment level the car has..this car is a 1997 c230

    FAULT CODES
    DTC Readout Descriptions

    026 CAN Bus Communication
    226 In-Car Air Temperature Sensor
    227 Outside Air Temperature Sensor
    228 Heater Core Temperature Sensor
    230 Evaporator Temperature Sensor
    231 Engine Coolant Temperature Sensor
    232 Refrigerant Pressure Sensor
    233 Refrigerant Temperature Sensor
    241 Refrigerant Level
    416 Coolant Circulation Pump
    417 Left Duovalve (Water Valve)
    418 Right Duovalve (Water Valve)
    419 A/C Compressor Electromagnetic Clutch
    420 Closed (Idle) Throttle Speed Increase
    421 Pulse Module
    422 Serial Interface Connection (K1) to Instrument Cluster
    451 Diverter Flap
    452 Blend Air Flap
    453 Fresh/Recirculated Air Flap Long Stroke
    454 Fresh/Recirculated Air Flap Short Stroke
    455 Defroster Outlet Flap Long Stroke
    456 Defroster Outlet Flap Short Stroke
    457 Footwell Flap Long Stroke
    458 Footwell Flap Short Stroke
    459 Serial Interface Connection (K2) to Instrument Cluster
    462 Wide Open Throttle (WOT) Position Signal – Diesel Engine Only follow me on twitter https://twitter.com/fupabox