2017 Good Quality TU-1F04 thermal wax actuator for air conditioner and compressor to Curacao Manufacturers

2017 Good Quality
 TU-1F04 thermal wax actuator for air conditioner and compressor to Curacao Manufacturers

Short Description:

Product Detail

Product Tags

We offer wonderful energy in high-quality and improvement,merchandising,product sales and marketing and advertising and procedure for Electric Linear Actuator 12v , Automatic Temperature Control Circuit , Automatic Temperature Control Vents , We will empower people by communicating and listening, Setting an example to others and learning from experience.
2017 Good Quality TU-1F04 thermal wax actuator for air conditioner and compressor to Curacao Manufacturers Detail:

1. Operation Principle

The Thermostatic Wax that has been sealed in shell body induces expansion by a given temperature, and inner rubber seal part drives its handspike to move under expansion pressure to realize a transition from thermal energy into mechanical energy. The Thermostatic Wax brings an upward movement to its handspike, and automatic control of various function are realized by use of upward movement of handspike. The return of handspike is accomplished by negative load in a given returned temperature.

2. Characteristic

(1)Small body size, occupied limited space, and its size and structure may be designed in according to the location where needs to work.

(2)Temperature control is reliable and nicety

(3)No shaking and tranquilization in working condition.

(4)The element doesn’t need special maintenance.

(5)Working life is long.

3.Main Technical Parameters

(1)Handspike’s height may be confirmed by drawing and technical parameters

(2)Handspike movement is relatives to the temperature range of the element, and the effective distance range is from 1.5mm to 20 mm.

(3)Temperature control range of thermal wax actuator is between –20 ~ 230℃.

(4)Lag phenomenon is generally 1 ~ 2℃. Friction of each component part and lag of the component part temperature cause a lag phenomenon. Because there is a difference between up and down curve of traveling distance.

(5)Loading force of thermal wax actuator is difference, it depends on its’ shell size.


Product detail pictures:

2017 Good Quality
 TU-1F04 thermal wax actuator for air conditioner and compressor to Curacao Manufacturers detail pictures


We take pleasure in an extremely fantastic standing among the our prospects for our great product top quality, competitive cost and the finest support for 2017 Good Quality TU-1F04 thermal wax actuator for air conditioner and compressor to Curacao Manufacturers, The product will supply to all over the world, such as: Mauritius , Swiss , Bogota , With its rich manufacturing experience, high-quality products, and perfect after-sale service, the company has gained good reputation and has become one of the famous enterprise specialized in manufacturing series.We sincerely hope to establish business relation with you and pursue mutual benefit.



  • This one shows how the oil pump is bled and what different conditions mean. This video is part of the heating and cooling series of training videos made to …



    Code
    #include 16f877a.h
    #device adc=10 // Set ADC resolution to 10Bit
    #fuses XT,NOLVP,NOWDT,NOPROTECT
    #use delay(clock=4000000)
    #use rs232(baud=9600,xmit=PIN_C6,rcv=PIN_C7,ERRORS)
    #include “flex_lcd.c”

    #define LOAD PIN_B7
    #define THRES 30.0 // load switching threshold in Celsius

    int16 digital_reading; // ADC resolution is 10Bit, an 8Bit integer is not enough to hold the reading
    float temp;

    void main()

    /* ADC Initialization */
    setup_adc(ADC_CLOCK_INTERNAL); // initialize ADC with a sampling rate of Crystal/4 MHz
    setup_adc_ports(RA0_ANALOG); // set PIN_A0 as analog input channel
    set_adc_channel(0); // point ADC to channel 0 for ADC reading
    delay_ms(1); // ADC module is slow, needs some time to adjust.

    /* Peripherals Configurations */
    lcd_init(); // Turn LCD ON, along with other initialization commands
    output_low(LOAD); // the load is initially OFF
    lcd_gotoxy(1,1); // point LCD cursor to col1 row1
    lcd_putc(“Temperature is:”); // print on LCD

    while(1) // infinite loop

    digital_reading = read_adc(); // capture current temperature reading
    delay_us(100); // 0.1ms delay for ADC stabilization
    temp = digital_reading * 0.4883; // convert reading to Celsius
    lcd_gotoxy(1,2); // point LCD cursor to col1 row2
    printf(lcd_putc,”%2.1f C”,temp); // print value on LCD

    if(temp=THRES) output_high(LOAD); // Control Load
    else output_low(LOAD);

    delay_ms(1000); // 1 second delay between readings